Bush AG56TBX Instruction Manual page 20

Table of Contents

Advertisement

Installing your gas cooker
Bringing it all together
the left and, with your other hand, lift the burner up
holding from the thermocouple/spark plug holder. The
injector is on the right-hand side of the burner cradle.
Repeat the same procedure for both the Main and Top
Oven (if present) burners.
Injector
Remove the injectors using a 7mm spanner and
replace the injector with the ones from the spare set.
Make sure you use corresponding diameters suitable
to the type of gas that is going to be used, according to
the information chart (which is also supplied in the gas
conversion kit).
Adjusting the minimum flame position
First of all, make sure that the appliance is unplugged
from the mains electrical supply and that the gas feed
is open. The minimum flame position is adjusted with
a flat screw located on the valve. As shown in the
figures; for valves with a flame failure safety device, the
screw is located on the side of the valve spindle and for
valves without a flame failure safety device, the screw is
located inside the valve spindle. To make adjusting the
flame position easier, we recommend that you remove
the control panel (and the micro switch if your model
has one) during the alteration. The bypass screw must
be loosened for conversion from LPG to natural gas.
For conversion from natural gas to LPG, the bypass
screw must be tightened.
If you require any technical guidance or find that your product is not operating as intended, a simple solution can often be found in the Troubleshooting section of these instructions,
Installing your gas cooker
20
Valve with flame failure
device
Clip
Bypass screw
Determining the minimum flame position
To determine the minimum position, ignite the burners
and leave them on in the minimum position. Remove
the knobs to gain access to the screws. With the help
of a small screwdriver, fasten or loosen the bypass
screw by around 90 degrees. When the flame has a
length of at least 4mm, the gas is well distributed. Make
sure that the flame does not die out when passing
from the maximum position to the minimum position.
Create an artificial wind with your hand towards the
flame to see if the flames are stable. For the oven
burner, operate the oven burner at the minimum
position for 5 minutes, then open and close the oven
door 2-3 times to check the flame stability of the
burner.
Bypass screw
Non-thermostatic
oven valve
Changing the gas inlet
For some countries, the gas inlet type can be different
Valve without flame failure
device
Screw(inside the hole)
Thermostatic oven valve
Bypass screw

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ag56twx

Table of Contents