When querying names, labels are surrounded by double quotes and each level is separated by commas ',' (multi-
level systems only) and each source is separated by newlines. Secondary levels use empty strings to indicate
that the label of the first level should be used.
Examples
>SrcNames
"Src1","AudSrc1"
"Src2",""
"Src3",""
"Src4",""
>SrcNames 1
"Src1","AudSrc1"
>SrcNames 1,2
"AudSrc1"
>SrcNames 1,2,""
>
The first 3 example commands are query commands. The last assigns an empty string to the second level of the
first source (thereby indicating that the first level label should be used).

3.11.44 SysName Command

NOTE: Superseded by the sys.name
Query or assign system name. The system name is provided for convenience when managing multiple Matrix
Switch Corporation systems. This value is stored and recalled on power up.
Command
SysName
SysName STR
Example for querying and assigning system name
>SysName
MSC-Router
>SysName "MyRouter"
>

3.11.45 SysType Command

Protocol Version: 2.3
NOTE: Superseded by the sys.arch
Query the system series type, which is currently defined as one of the following values:
Value Series name
0
Carina
1
Lupus
Page 48 of 60