Whirlpool YCEM2765FQ Installation Instructions Manual page 20

Commercial dryer gas or electric
Table of Contents

Advertisement

Available languages

Available languages

ELECTRIC DRYER ELECTRICAL CONNECTIONS
Connecting 3-Wire Connection: Power Supply Cord (cont.)
3. Connect remaining wires under outer terminal block screws
(F). Tighten screws. Finally, reinstall terminal block cover to
dryer rear panel. Secure cover with hold-down screw. Now
go to "Venting Requirements."
Direct Wire Connection
Remove Terminal Block Cover
Remove hold-down screw and terminal block cover.
20
F
F
Direct Wire Strain Relief
1. Insert strain relief.
Unscrew the removable conduit connector (A) and any
screws from a ¾" (19 mm) UL listed strain relief (UL marking
on strain relief). Put the threaded section of the strain relief
(C) through the hole below the terminal block opening (B).
Reaching inside the terminal block opening, screw the
removable conduit connector (A) onto the strain relief threads.
2. Insert conduit into strain relief and tighten clamp.
Put direct wire cable through the strain relief. The strain
relief should have a tight fit with the dryer cabinet and be in
a horizontal position. Tighten strain relief screw against the
direct wire cable.
(FOR U.S.A. ONLY)
A
B
C

Advertisement

Table of Contents
loading

Table of Contents