Becker M04a Assembly And Operating Instructions Manual

Roller shutter and sun protection drives with mechanical limit switch

Advertisement

Quick Links

P4-30...L100-11
Model: M04a
Assembly and Operating Instructions
en
Roller shutter and sun protection drives with
mechanical limit switch
Important information for:
• Fitters / • Electricians / • Users
Please forward accordingly!
These instructions must be kept safe for future reference.
2010 301 083 0     14/08/2018   
Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the M04a and is the answer not in the manual?

Questions and answers

Summary of Contents for Becker M04a

  • Page 1 P4-30...L100-11 Model: M04a Assembly and Operating Instructions Roller shutter and sun protection drives with mechanical limit switch Important information for: • Fitters / • Electricians / • Users Please forward accordingly! These instructions must be kept safe for future reference.
  • Page 2: Table Of Contents

    Table of contents General .................................... 3 Warranty .....................................  3 Safety instructions ................................ 4 Instructions for the user.............................. 4 Instructions for installation and commissioning........................ 4 Intended use .................................. 6 Assembling and disassembling the plug-in connecting cable.................... 6 Assembling the plug-in connecting cable ..........................  6 Disassembling the plug-in connecting cable for tubular drives dia.
  • Page 3: General

    General These tubular drives are high-quality products with the following features: • For use with roller shutters • For use with sunblinds • Easy limit switch setting on the drive • Compatible with all of the drive manufacturer's control units for roller shutters and sunblinds •...
  • Page 4: Safety Instructions

    Safety instructions The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury. Instructions for the user General information • The drive must be disconnected from its power source during cleaning and maintenance and when re- placing parts.
  • Page 5 • Hazardous moving parts of the drive must be installed at a height of over 2.5 m above floor level or any other surface from which the drive can be accessed. • To ensure safe operation of the system after commissioning, the limit positions must be correctly set/ programmed in.
  • Page 6: Intended Use

    Intended use The type of tubular drive described in these instructions is intended solely for the operation of roller shutters and sun protection systems. We recommend using drives with more than 17 rpm only in sun protection systems (screens). When mounting connection parts on the drive dia. 35 mm PXX/XX, only use screws EJOT Delta PT 40x12 WN 5454 Torx (9900 000 545 4).
  • Page 7: Disassembling The Plug-In Connecting Cable For Tubular Drives Dia. 35

    Disassembling the plug-in connecting cable for tubular drives dia. 35. Caution Prior to disassembly, the power supply to the connecting cable must be disconnected. Insert a suitable flathead screwdriver between the locating lug and the snap-in pin, so that the snap-in pin releases the locating lug from the plug.
  • Page 8: Disassembling The Plug-In Connecting Cable For Tubular Drives Dia. 45 And Dia. 58

    Disassembling the plug-in connecting cable for tubular drives dia. 45 and dia. 58 Caution Prior to disassembly, the power supply to the connecting cable must be disconnected. Insert a suitable flathead screwdriver right into the recess of the locating latch, so that the latch releases the locating lug from the plug.
  • Page 9: Installation

    Installation Assembling the drive Attention To connect the drive to the driven part, solely mechanical accessory components made by the drive manufacturer from the current product catalogue may be used. Prior to mounting, the fitter must ensure that the masonry and the system being motorised are sufficiently robust (drive torque plus weight of the shading solution).
  • Page 10: Disassembling The Drive Adapter With Safety Catch On The Drive Shaft

    Disassembling the drive adapter with safety catch on the drive shaft Disassembly with disassembly tool, Item no. 4930 300 606 0 Disassembly with long nose pliers Assembling and disassembling the drive adapter with separate drive adapter safety catch Assembling and disassembling the drive adapter with screw connection Mounting the drive in the tube For profile tubes: In the case of some drive adapters, tolerances of the groove widths in different bar-...
  • Page 11 For round shafts: Measure the lug of the thrust ring (X, Y). Then notch the tube on the motor side, so the lug of the thrust ring can also be pushed into the shaft. There must be no play between the lug of the thrust ring and the shaft. To ensure secure torque transmission for round shafts, we recommend screwing the drive adapter to the shaft (see the table below).
  • Page 12: Setting The Limit Positions

    Setting the limit positions Upper limit position Lower limit position Lower limit position Upper limit position Setting the lower limit position 1. Before the shading solution is fixed to the barrel, let the drive run DOWN until it switches off automatically. 2.
  • Page 13: Information For The Electrician

    The packaging material must be disposed of properly. Maintenance These drives are maintenance-free. Technical data dia. 35 Tubular drive P4-30 Model M04a Type C M A Rated torque [Nm] Output speed [rpm] Limit switch range 38 revolutions Supply voltage...
  • Page 14: Technical Data Dia. 45

    Technical data dia. 45 Tubular drive R8-17 R12-17 R15-17 R20-17 Model M04a Type C M A Rated torque [Nm] Output speed [rpm] Limit switch range 38 revolutions Supply voltage 240 V AC / 50 Hz Connected load [W] Rated current consumption [A] 0.45...
  • Page 15: Technical Data Dia. 58

    Technical data dia. 58 Tubular drive L60-11 L80-11 L100-11 Model M04a Type C M A Rated torque [Nm] Output speed [rpm] Limit switch range 36 revolutions Supply voltage 240 V AC / 50 Hz Connected load [W] Rated current consumption [A] 1.05 1.30 1.95 Operating mode S2 4 min...
  • Page 16: Sample Wiring Diagrams

    Sample wiring diagrams Control via a single switch/button Central, group and individual control using Centronic UnitControl UC42 Central Control unit Mains 230 V / 50 Hz Central cable 230 V / 50 Hz (connection to further control units) Group 230 V / 50 Hz Individual Individual 230 V / 50 Hz...