Important Hints; Symbols; Unpacking; Positioning - Hameg HM8135X Manual

3 ghz rf-synthesizer
Hide thumbs Also See for HM8135X:
Table of Contents

Advertisement

Available languages

Available languages

I m p o r t a n t h i n t s

Important hints

Symbols

!
(1)
(2)
(3)
Symbol 1:
Attention, please consult manual
Symbol 2:
Danger! High voltage!
Symbol 3:
Ground connection
Symbol 4:
Important note
Symbol 5:
Stop! Possible instrument damage!

Unpacking

Please check for completeness of parts while unpacking. Also
check for any mechanical damage or loose parts. In case of
transport damage inform the supplier immediately and do not
operate the instrument.
Check setting of line voltage selector whether it corresponds
to the actual line voltage.

Positioning

Two positions are possible: According to picture 1 the front
feet are used to lift the instrument so its front points slightly
upward. (Appr. 10 degrees)
If the feet are not used the instrument can be combined with
many other Hameg instruments.
In case several instruments are stacked the feet rest in the
recesses of the instrument below so the instruments can
not be inadvertently moved. Please do not stack more than 3
instruments. A higher stack will become unstable, also heat
dissipation may be impaired.
picture 1
picture 2
picture 3
26
Subject to change without notice
STOP
STOP
(4)
(5)
STOP

Transport

Please keep the carton in case the instrument may require
later shipment for repair. Improper packaging may void the
warranty!

Storage

Dry indoors storage is required. After exposure to extreme
temperatures 2 h should be allowed before the instrument is
turned on.

Safety instructions

The instrument conforms to VDE 0411/1 safety standards appli-
cable to measuring instruments and left the factory in proper
condition according to this standard. Hence it conforms also
to the European standard EN 61010-1 resp. to the internatio-
nal standard IEC 61010-1. Please observe all warnings in this
manual in order to preserve safety and guarantee operation
without any danger to the operator. According to safety class 1
requirements all parts of the housing and the chassis are con-
nected to the safety ground terminal of the power connector.
For safety reasons the instrument must only be operated from
3 terminal power connectors or via isolation transformers. In
case of doubt the power connector should be checked according
to DIN VDE 0100/610.
Disconnecting the protective earth internally or
externally is absolutely prohibited!
The line voltage selector must be properly set for the line
voltage used.
Opening of the instrument is allowed only to qualifi ed per-
sonnel
Prior to opening the instrument must be disconnected from
the line and all other inputs/outputs.
In any of the following cases the instrument must be taken out
of service and locked away from unauthorized use:
Visible damages
Damage to the power cord
Damage to the fuse holder
Loose parts
No operation
After longterm storage in an inappropriate environment ,
e.g. open air or high humidity.
Excessive transport stress

Operating conditions

The instruments are destined for use in dry clean rooms. Ope-
ration in an environment with high dust content, high humidity,
danger of explosion or chemical vapors is prohibited.
Operating temperature is 0 .. +40 degrees C. Storage or trans-
port limits are –20 .. +55 degrees C. In case of condensation two
hours are to be allowed for drying prior to operation.
For safety reasons operation is only allowed from 3 terminal
connectors with a safety ground connection or via isolation
transformers of class 2. The instrument may be used in any
position, however, suffi cient ventilation must be assured as
convection cooling is used. For continuous operation prefer a
horizontal or slightly upward position using the feet.

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Hm8135