Hameg HM8134-3X Handbuch Manual
Hameg HM8134-3X Handbuch Manual

Hameg HM8134-3X Handbuch Manual

1.2 ghz rf - synthesizer
Hide thumbs Also See for HM8134-3X:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

1 . 2 G H z R F - S y n t h e s i z e r
H M 8 1 3 4 - 3
Handbuch / Manual
Deutsch / English

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HM8134-3X and is the answer not in the manual?

Questions and answers

Summary of Contents for Hameg HM8134-3X

  • Page 1 1 . 2 G H z R F - S y n t h e s i z e r H M 8 1 3 4 - 3 Handbuch / Manual Deutsch / English...
  • Page 2: Allgemeine Hinweise Zur Ce-Kennzeichnung

    D-63533 Mainhausen DECLARATION DE CONFORMITE Sicherheit / Safety / Sécurité Die HAMEG Instruments GmbH bescheinigt die Konformität für das Produkt The HAMEG Instruments GmbH herewith declares conformity of the product Sicherheit / Safety / Sécurité: EN 61010-1:2001 (IEC 61010-1:2001) HAMEG Instruments GmbH déclare la conformite du produit Überspannungskategorie / Overvoltage category / Catégorie de surtension: II...
  • Page 3: Table Of Contents

    I n h a l t s v e r z e i c h n i s English PREV.-Taste ON-Taste Deutsch RCL- / STO-Tasten (Recall/Store) Allgemeine Hinweise zur CE-Kennzeichnung Fernbedienung Schnittstellen 1,2 GHz HF-Synthesizer HM8134-3 Unterstützte Befehle Bedeutung der Fehlercodes Technische Daten Flussdiagramme (Flow charts) Wichtige Hinweise...
  • Page 4 H M 8 1 3 4 - 3 1 , 2 G H z H F - S y n t h e s i z e r H M 8 1 3 4 - 3 Weiter Frequenzbereich von 1 Hz bis 1,2 GHz HZ42 19“...
  • Page 5: Ghz Hf-Synthesizer Hm8134-3

    HM8134-3D/150507/ce · Änderung vorbehalten · © HAMEG Instruments GmbH · ® Registered Trademark · DQS-zertifiziert nach DIN EN ISO 9001:2000, Reg. Nr.: DE-071040 QM HAMEG Instruments GmbH · Industriestr. 6 · D-63533 Mainhausen · Tel +49 (0) 6182 800 0 · Fax +49 (0) 6182 800 100 · www.hameg.com · info@hameg.com A Rohde &...
  • Page 6: Wichtige Hinweise

    Schwere Transportbeanspruchung Gewährleistung und Reparatur Bleiben die vorderen Gerätefüße eingeklappt, wie in Abbildung 2, lässt sich das Gerät mit vielen weiteren Geräten von HAMEG sicher stapeln. Werden mehrere Geräte aufeinander gestellt HAMEG Geräte unterliegen einer strengen Qualitätskontrolle. sitzen die eingeklappten Gerätefüße in den Arretierungen des Jedes Gerät durchläuft vor dem Verlassen der Produktion einen...
  • Page 7: Bestimmungsgemäßer Betrieb

    Reinigungsmittel kann die Kunststoff- und stungsfrist wenden Sie sich bitte an den Händler, bei dem Lackoberfl ächen angreifen. Sie Ihr HAMEG Produkt erworben haben. Um den Ablauf zu Netzspannungsumschaltung beschleunigen, können Kunden innerhalb der Bundesrepublik Deutschland die Gewährleistungsreparatur auch direkt mit HAMEG abwickeln.
  • Page 8 B e d i e n u n g s e l e m e n t e H M 8 1 3 4 - 3 NUMERISCHE TASTATUR: Eingabeparameter mit Maß- Bedienungselemente HM8134-3 einheit ON: Taste zur Aktivierung des Ausgangs Geräte-Frontseite ESC (Escape): Taste zum Rücksprung ins Hauptmenü...
  • Page 9: Einführung In Die Bedienung Des Hm8134-3

    D i e B e d i e n u n g d e s H M 8 1 3 4 Einführung in die Bedienung des HM8134-3 Die Bedienung des HM8134-3 Inbetriebnahme Display Beachten Sie bitte besonders bei der ersten Inbetriebnahme Die Anzeige zeigt die Frequenz und den Pegelwert des RF- des Gerätes folgende Punkte: Ausgangssignals, sowie die verwendete Referenz (INTern oder...
  • Page 10: Wahl Des Pegels

    D i e B e d i e n u n g d e s H M 8 1 3 4 - 3 Ein neuer Funktionswert kann über die Tastatur , mit Die Parameterauswahl für die Funktionen AM/FM/PM erfolgt dem Drehknopf oder mit den kontextsensitiven Tasten erneut über die kontextsensitiven Tasten eingestellt werden.
  • Page 11: Modulationsarten

    M o d u l a t i o n s a r t e n Beispiel 1: CH1 — > Demoduliertes Signal: DC gekoppelt CH2 — > Demoduliertes Signal: AC gekoppelt Mit der PREV.-Taste wird zum vorherigen Menüpunkt zurückgeschaltet. Mit der ESC-Taste wird zum Haupt- Display umgeschaltet.
  • Page 12: Frequenzmodulation (Fm)

    M o d u l a t i o n s a r t e n Frequenzmodulation (FM) Beispiel 4: Für AM Rechteck (Modulationsgrad: 50%) erhält man: Nach Auswahl der Option DEV (FM MENU) mittels der kontext- sensitiven Tasten zeigt das Display: Ein neuer Funktionswert kann über die Tastatur , mit dem Drehgeber...
  • Page 13: Phasenmodulation (Pm)

    M o d u l a t i o n s a r t e n Phasenmodulation (PM) FSK Modulation Nach Auswahl der Option DEV (PM MENU) mittels der kontext- Nach Auswahl der Optionen F0 oder F1 (FSK-MENU) mittels sensitiven Tasten zeigt das Display: der kontextsensitiven Tasten zeigt das Display:...
  • Page 14: Gate Modulation

    E i n s t e l l u n g d e r G e r ä t e k o n f i g u r a t i o n Beispiel 14: (Fgate: 250 Hz Sqr) GATE Psk0: –3,14 rad;...
  • Page 15: Menu-Taste

    Referenzoszillators (verriegelt und entriegelt). Die interne diesem Menu nicht aufgeführt sein, setzen Sie sich Referenzfrequenz ist über den Ausgang REF. OUPUT 10 MHz bitte mit dem HAMEG Service (service@hameg.de ) verfügbar. Die Zufuhr einer externen Referenzfrequenz ist über in Verbindung.
  • Page 16: Prev.-Taste

    F e r n b e d i e n u n g Fstr: 16.000000 MHz Nach Betätigung der STO-Taste zeigt das Display: – stp + Fstp: 1200.000000 MHz Die aktuelle Konfi guration wird mit einer Zahl zwischen 0-9 – stp + (numerische Tastatur) abgespeichert.
  • Page 17: Unterstützte Befehle

    F e r n b e d i e n u n g Der Anwender kann mit dem Befehl LK1 alle Bedienungsele- Fernsteuerung aus mente sperren. Das Display zeigt dann: Fernsteuerung ein Sound Befehle Beep aus leiser Beep Unterstützte Befehle lauter Beep Allgemein Befehle OUTPUT...
  • Page 18 F e r n b e d i e n u n g string folgt automatisch die Bezeichnung der Einheit Hz (z.B. Befehlszeile (1) dient Modulationsgradeinstellung. Der <NUM> 34000000 Hz für 34 MHz). Die Optionen :CW und :FIXed haben Parameter ist ein bereichsspezifi scher NR2 Daten-string (siehe auf das Instrument keine Wirkung.
  • Page 19 F e r n b e d i e n u n g Befehle PM (Phase Modulation) oder NR3 Datenstring (siehe Abschnitt Syntaxkonvention). Dem Datenstring folgt automatisch die Bezeichnung der Einheit Hz (z.B. 34000000Hz für 34 MHz). Phasenmodulation Befehlszeile (2) dient der aktuellen Frequenzhubabfrage. Das Syntax: Instrument sendet einen NR3 Datenstring ohne Einheit.
  • Page 20 F e r n b e d i e n u n g Das Instrument sendet 0 bei nicht aktivierter PM Modulation Die Befehlszeilen (3) und (5) dienen der PSK Phaseneinstellung und sendet 1 bei aktivierter PM Modulation. (PH0 bzw. PH1). Der <NUM> Parameter ist ein bereichsspe- zifi...
  • Page 21: Bedeutung Der Fehlercodes

    F e r n b e d i e n u n g Beispiel: FM oder PM Frequenzmodulation Fehler :SWE:TIME 5; :FREQ:STAR 16E+6;:FREQ:STOP 1.2E+9; :FREQ: (erlaubter Bereich: 10 Hz – 100 kHz) MODE SWE PM Frequenzhub Fehler (erlaubter Bereich: 0 rad – 3.14 rad) Befehle SYSTEM PM Frequenzhub Fehler (erlaubter Bereich: 0 rad –...
  • Page 22: English

    HAMEG instruments fulfi ll the regulations of the EMC directive. The Signal lines must screened (coaxial cable - RG58/U). A proper ground conformity test made by HAMEG is based on the actual generic- and connection is required. In combination with signal generators double product standards.
  • Page 23 C o n t e n t s Deutsch ON key RCL/STO keys English Remote operation Declaration of Conformity Interfaces Commands supported 1.2 GHz RF-Synthesizer Error codes and their meaning Specifi cations Flow charts Important hints Tables Symbols Unpacking Positioning Transport Storage Safety instructions...
  • Page 24: 1 . 2 G H Z R F - S Y N T H E S I Z E R

    H M 8 1 3 4 - 3 1 . 2 G H z R F - S y n t h e s i z e r H M 8 1 3 4 - 3 Frequency range from 1 Hz to 1.2 GHz HZ42 19“...
  • Page 25: Specifi Cations

    HM8134-3E/151007/ce · Subject to alterations · © HAMEG Instruments GmbH · ® Registered Trademark · DQS-certified in accordance with DIN EN ISO 9001:2000, Reg.-No.: DE-071040 QM HAMEG Instruments GmbH · Industriestr. 6 · D-63533 Mainhausen · Tel +49 (0) 6182 800 0 · Fax +49 (0) 6182 800 100 · www.hameg.com · info@hameg.com A Rohde &...
  • Page 26: Important Hints

    The line voltage selector must be properly set for the line voltage used. If the feet are not used the instrument can be combined with many other Hameg instruments. – Opening of the instrument is allowed only to qualifi ed per-...
  • Page 27: Warranty And Repair

    Warranty and Repair pressing the top of the fuse holder down. The top holding the HAMEG instruments are subject to a strict quality control. All fuse will then come off. Exchange the defective fuse against a instruments are burned in for 10 hrs prior to shipment. By in- correct new one.
  • Page 28: Designation Of Operating Controls

    D e s i g n a t i o n o f O p e r a t i n g c o n t r o l s Designation of Operating controls Front panel Key for activation the output POWER (button) ESC (Escape) Power switch and led...
  • Page 29: Introduction Of The Hm8134-3

    O p e r a t i n g t h e i n s t r u m e n t Indroduction of the HM8134-3 Operating the instrument First time operation Main display Before starting the instrument the fi rst time, please check the This display shows the frequency and the level of the RF output following: signal and the reference in use (INTernal or EXTernal).
  • Page 30: Selecting Level

    O p e r a t i n g c o n t r o l s The resolution is 1 Hz. If a value is entered with a higher – The shape of internal modulation signal resolution, the instrument makes a truncation keeping 1 Hz –...
  • Page 31: Types Of Modulation

    T y p e s o f M o d u l a t i o n Example 1: CH1— > demodulated signal: DC coupled CH2— > demodulated signal: AC coupled The return to the modulation menu is possible by pressing the PREV.
  • Page 32: Frequency Modulation (Fm)

    T y p e s o f M o d u l a t i o n Frequence modulation (FM) Example 4: For AM square (depth: 50%), the display shows: After selecting DEV (FM MEMU) using the context sensitive keys , the display shows: A new value of the deviation can be entered from the data keypad...
  • Page 33: Phase Modulation (Pm)

    T y p e s o f M o d u l a t i o n Phase modulation (PM) FSK modulation After selecting DEV (PM MEMU) using the context sensitive keys After selecting F0 or F1 (FSK MENU) with the context sensitive , the display shows: , the display shows: Fsk0:...
  • Page 34: Gate Modulation

    S e t t i n g t h e c o n f i g u r a t i o n The GATE modulation can be active with another modulation (for example the GATE modulation with AMsin modulation and Fmod = 10 kHz) Example 14 (Fgate: 250Hz Sqr): GATE...
  • Page 35: Menu Key

    (locked or unlocked). Increased contact the HAMEG Service (serciec@hameg.de). stability for the HM8134-3 may be obtained from an external oscil- lator. The external reference frequency must be applied to the REF.
  • Page 36: Prev. Key

    S e t t i n g t h e c o n f i g u r a t i o n ON key The parameters are selected by pressing one of the four context sensitive keys The output RF OUTPUT is only active if the ON key pressed and the corresponding LED is lighted.
  • Page 37: Remote Operation

    R e m o t e O p e r a t i o n lower case and upper case are the same. A simple command Remote Operation gives an access to a quantity or a function of the instrument. All commands acting on the same quantity are brought together in a tree structure.
  • Page 38 O p e r a t i n g c o n t r o l s POWER Sending line (2) the instruments returns which source is cur- rently selected. The instrument sends back the strings INT or Commands in order to change the level of the RF output si- EXT corresponding to the 2 options described above.
  • Page 39 O p e r a t i n g c o n t r o l s Sending line (6) the instruments returns the current modu-lation Sending line (7) the shape of the internal modulation signal can frequency. The instrument sends back a string representing a be changed.
  • Page 40 O p e r a t i n g c o n t r o l s turns the current modulation frequency. The instrument sends back a string representing a NR3 decimal number. Commands in order to modify PSK parameters. :PM:INTern:SHAPe SIN | SQU Syntax: :PM:INTern:SHAPe?
  • Page 41: Error Codes And Their Meaning

    O p e r a t i n g c o n t r o l s the resolution. Sending line (5) and (7) the instrument returns FM deviation error (must be in the range the two frequencies START and STOP. It sends back a string 2 kHz - 400 kHz) representing a NR3 decimal number.
  • Page 42: Flussdiagramme (Flow Charts)

    F l o w - C h a r t s Function selection Step control Subject to change without notice...
  • Page 43 F l o w - C h a r t s Amplitude Modulation Control GATE GATE Subject to change without notice...
  • Page 44 F l o w - C h a r t s Phase Modulation Control GATE GATE Subject to change without notice...
  • Page 45 F l o w - C h a r t s Frequency Modulation Control GATE GATE Subject to change without notice...
  • Page 46 F l o w - C h a r t s FSK Modulation Control S T A T U S 400.000000MHz F S K 1200.000000MHz F I X PREV 410.000000MHz 13.0dBm REFint MOD. MOD. MODULATION MENU MODULATION MENU < - - - - >...
  • Page 47 F l o w - C h a r t s PSK Modulation Control S T A T U S 1200.000000MHz P S K 1200.000000MHz F I X PREV 13.0dBm 13.0dBm REFint MOD. MOD. MODULATION MENU MODULATION MENU < - - - - >...
  • Page 48 F l o w - C h a r t s Gate Control GATE GATE Subject to change without notice...
  • Page 49 F l o w - C h a r t s Main Menu Control Sweep Sweep INTERFACE TYPE INTERFACE TYPE INTERFACE TYPE INTERFACE TYPE INTERFACE TYPE INTERFACE TYPE SERIAL SERIAL SERIAL SERIAL SERIAL SERIAL RS232 (DEFAULT) RS232 (DEFAULT) 4800 4800 NONE NONE Subject to change without notice...
  • Page 50 F l o w - C h a r t s Sweep Control S T A T U S 1200.000000MHz F I X 13.0dBm REFint PREV MENU * * * * * * * * MAIN MENU Sweep * * * SWEEP MENU * * * * * *...
  • Page 51: Umrechnungstabellen

    T a b l e s Conversion ρ ↔ V. S.W.R. REFLECTED FACTOR STATIONARY WAVE RATIO ρ − ρ = VSWR = − ρ VSWR VSWR VSWR VSWR |ρ| |ρ| |ρ| |ρ| 0.00 1.00 0.25 1.67 0.50 3.00 0.75 7.00 0.01 1.02 0.26...
  • Page 52 T a b l e s Conversion dBm ↔ Volt CONVERSION dBm → Volt CONVERSION Volt → dBm ⋅ ⋅ ⋅ ⋅ Ω with: Volt Volt Volt Volt Volt +20.0 2.236 +16.0 1.411 +12.0 0.890 +8.0 0.562 +4.0 0.354 +19.9 2.210 +15.9 1.395...
  • Page 53 T a b l e s Conversion dBm ↔ mW CONVERSION mW → dBm CONVERSION dBm → mW ⋅ ⋅ with: P +20.0 100.000 +16.0 39.811 +12.0 15.849 +8.0 6.310 +4.0 2.512 +19.9 97.724 +15.9 38.905 +11.9 15.488 +7.9 6.166 +3.9 2.455 +19.8...
  • Page 54 T a b l e s Conversion dBm ↔ Ratio CONVERSION Ratio → dBm CONVERSION dBm → Ratio ⋅ = 10 20 log Ratio Ratio Ratio Ratio Ratio 1.000 1.698 2.884 13.8 4.898 18.4 8.318 1.012 1.718 2.917 13.9 4.955 18.5 8.414 1.023...
  • Page 55 T a b l e s Conversion dBμV ↔ Volt CONVERSION Volt → dBµV CONVERSION dBµV → Volt μ dB V ⋅ ⋅ μ dB V = μV with: U dBµV µVolt dBµV µVolt dBµV mVolt dBµV mVolt dBµV Volt 1.00 1.00 1.00...
  • Page 56 . h a m e g . c o m Subject to change without notice 45-8134-0311/07122007 gw HAMEG Instruments GmbH © HAMEG Instruments GmbH Industriestraße 6 A Rohde & Schwarz Company D-63533 Mainhausen ® registered trademark Tel +49 (0) 61 82 800-0 DQS-Certifi...

This manual is also suitable for:

Hm8134-3

Table of Contents