14-Pin Remote Control Receptacle - SanRex SANARG 200AP Operator's Manual

Ac/dc inverter arc welder
Table of Contents

Advertisement

4.3

14-PIN REMOTE CONTROL RECEPTACLE

FIGURE 4-2 : 14-PIN Remote Control Receptacle Layout.
Socket
I/O
Pin
Input
A
Torch Switch Input. To energize weld current, connect pins A & B.
B
Input
Torch Switch Input. To energize weld current, connect pins A & B.
C
Output
+10VDC signal connects to high side of 1k ohm remote control potentiometer.
GND
D
Zero ohm (minimum) connection to low side of 1k ohm remote control potentiometer.
E
Input
Wiper arm connection to 1k ohm remote control potentiometer, (0 to +10VDC signal)
F
N/C
Not used
G
GND
Internally connected to chassis ground.
Not used
H
N/C
Not used
I
N/C
Not used
J
N/C
Not used
K
N/C
L
N/C
Not used
M
Output
OK TO MOVE (current detect signal, dry contact closure to pin N)
N
Output
OK TO MOVE (current detect signal, dry contact closure to pin M)
TABLE 4-1 : 14-PIN Remote Control Receptacle Pin-Out Description.
The 14-PIN Remote Control Contactor has the capability to operate by
Function
NOTE:
shorting pin set A-B
42