Input power of Environmental controlled anti-condensation
Environmental controlled anti-condensation heater
Anti-condensation heaters are turned on and off according to the control logic,
which is affected by ambient temperature and humidity condition in a normal
temperature setting. (Freezer compartment -18°C, Refrigerator compartment 4°C),
The input power of environmental controlled anti-condensation heater is given in
below table.
GR-B24FWAHL / GR-B24FWSHL
Mullion heater
Running rate in percentage(R) at
Relative
the ambient temperature(i)(%)
Humidity
16°C
0-10%
0.00
10-20%
0.06
20-30%
0.60
30-40%
2.76
40-50%
6.93
50-60%
8.01
60-70%
5.55
70-80%
3.30
80-90%
1.80
90-100%
0.99
GR-B24FWVFC
Mullion heater
Running rate in percentage(R) at
Relative
the ambient temperature(i)(%)
Humidity
16°C
0-10%
0.00
10-20%
0.06
20-30%
0.60
30-40%
2.76
40-50%
6.93
50-60%
8.01
60-70%
5.55
70-80%
3.30
80-90%
1.80
90-100%
0.99
heater / Defrost period
22°C
32°C
0.00
0.03
0.06
0.33
1.62
2.35
9.24
2.56
12.72
3.57
11.70
1.11
11.40
0.05
7.92
0.00
3.48
0.00
1.86
0.00
22°C
32°C
0.00
0.03
0.06
0.33
1.62
2.35
9.24
2.56
12.72
3.57
11.70
1.11
11.40
0.05
7.92
0.00
3.48
0.00
1.86
0.00
Input power at the ambient
temperature
16°C
22°C
1.765
1.765
1.765
1.765
1.765
1.765
1.765
1.765
1.765
1.765
3.941
3.941
3.941
3.941
3.941
3.941
5.882
5.882
5.882
5.882
Input power at the ambient
temperature
16°C
22°C
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.756
1.513
1.513
2.017
2.017
2.269
3.025
5.042
3.529
5.042
32°C
2.941
2.941
2.941
2.941
2.941
5.411
5.411
5.411
5.882
5.882
32°C
0.000
0.000
0.000
1.513
2.017
3.025
4.033
4.538
5.042
5.042

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gr-b24fwshlGr-b24fwvfcGr-m24fbghc

Table of Contents