ELECTRICAL CONNECTIONS

IMPORTANT: Ensure that the electricity supply is switched off before connecting.
Your appliance must be connected to fixed wiring via the use of a double pole switched fused spur outlet
with at least 3mm contact separation, The isolation switch must be accessible after installation. (See
technical data for fuse rating).
We strongly recommend the appliance is connected by a qualified electrician who is a member of the
N.I.C.E.I.C. or Corgi who will comply with the I.E.E and any local regulations.
NOTE: The terminology DOUBLE POLE -/+ means that both the live and neutral supplies are switched and
disconnected at the same time.
The terminations labelled SUPPLY are for the connection for the internal house wiring and the
terminations labelled LOAD are for the connection for the appliance.
IMPORTANT: The wires in the mains lead are coloured in accordance with the following code:-
Blue..........Neutral
Brown......Live
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured
markings identifying the terminals in your spur box, proceed as follows;
The wire which is coloured blue must be connected to the terminal which is marked with the letter 'N' or
coloured BLACK. The wire which is coloured brown must be connected to the terminal which is marked
with the letter 'L' or coloured RED.
FUSE
Fig 8. (Fused Switch)
BLUE
(NEUTRAL)
ON
BROWN
(LIVE)
Page 9
L
LOAD
ON
FUSE
BLUE
(NEUTRAL)
L
LOAD
L
N
SUPPLY
LOAD
DP
13A 250V~
N
SUPPLY
Fig 9. Wireing Example
TECHNICAL DATA
FUSE RATING:
3AMP
BROWN
(LIVE)
www.howdens.com