Start-Up; Before Starting Up For The First Time; Connecting The Appliance To The Mains Supply; Peration - Gastro-Cool GCFC100 Instructions For Use Manual

Chest freezer / cooler
Table of Contents

Advertisement

Available languages

Available languages

The climate classification can be found on the identification plate located on
the outside of the appliance at the back. The table to the side here shows which
ambient temperature is assigned to which climate classification:
Test room
Dry bulb
climate class
20°C
0
16°C
1
22°C
2
25°C
3
30°C
4
40°C
5
27°C
6
35°C
7

7 Start-up

7.1 Before starting up for the first time
After transportation the appliance should be left to stand for at least 24 hours so
that the refrigerant can collect in the compressor. Non-observance of this may
damage the compressor and so lead to the appliance malfunctioning. In such a case
the warranty becomes invalid.
Clean the interior of the refrigerator and all of the accessories to
be found here with commercially available, mild cleaning products.
WARNING: Do not store explosive substances such as aerosol cans with a
flammable propellant in this appliance.
The shelf can withstand the maximum load 4.5 kg.
30
Relative
Water weight in
Dew point
humidity
dry air
50%
9.3°C
7.3 g/kg
80%
12.6°C
9.1 g/kg
65%
15.2°C
10.8 g/kg
60%
16.7°C
12 g/kg
55%
20.0°C
14.8 g/kg
40%
23.9°C
18.8 g/kg
70%
21°C
15.8 g/kg
75%
30°C
27.3 g/kg
7.2 Connecting the appliance to the mains supply
IMPORTANT
It is imperative that the appliance be earthed according to the directions.
For this purpose the plug of the connecting cable is provided with the
appropriate contact.
IMPORTANT
Call a specialist electrician if the plug does not fit into the socket. Do not try
to force the plug into the socket.
IMPORTANT
If you disconnect the appliance from the mains supply, or if a power cut
occurs: wait for 5 minutes before you restart the appliance.
8 Operation
8.1

Switching the appliance on

In order to switch on the appliance push the mains plug into the socket.
8.2 Setting the temperature
The temperature can be set at GCFC100 from –24°C to 10°C.
Our recommendation is about 4°C.
A. Digitales Temperature Display
B. Light switch button
C. Fast freezing button
D. Fast freezing indicator
E. Setting button
A
B
C D
E
31

Advertisement

Chapters

Table of Contents
loading

Table of Contents