INSTALLATION INSTRUCTIONS
V VENT TERMINAL
Horizontal Vent Terminal Location for Direct Vent
The following information should be used for determining the proper location of the vent terminal for direct vent
water heaters.
A= Clearance above grade, veranda,
B= Clearance to window or door that
C= Clearance to permanently closed
window.
D= Vertical Clearance to ventilated
E= Clearance to unventilated soffit.
F= Clearance to outside corner.
G= Clearance to inside corner.
H = Clearance to each side of center line
I = Clearance to service regulator vent
J = Clearance to nonmechanical air
K = Clearance to mechanical air
L = Clearance above paved sidewalk
M = Clearance under veranda, porch,
1 In accordance with current CAN/CSA-B149.1 Installation Codes.
2 In accordance with current ANSI Z223.1/ NFPA 54 National Fuel Gas Code.
+ A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family
dwellings and serves both dwellings.
*
"Clearance in accordance with local installation codes and the requirements of the gas supplier."
38
Fixed
closed
Operable
X AIR SUPPLY INLET
porch, deck or balcony.
may be opened.
soffit located above the terminal
within a horizontal distance of 2
feet (61 cm) from the center line of
the terminal.
extended meter/regulator assembly.
outlet.
supply inlet to the building or the
combustion air inlet of any other
appliance.
supply inlet.
or paved driveway located on
public property.
deck or balcony.
Inside
corner detail
Fixed
closed
Operable
AREA WHERE TERMINAL IS NOT PERMITTED
Canadian Installations
1
12 inches (30 cm)
6 inches (15 cm) for appliances < 10,000
Btuh (3 kW), 12 inches (30 cm) for
appliances > 10,000 Btuh (3kW) and
< 100,000 Btuh (30kW), 36 inches (91 cm)
for appliances > 100,000 Btuh (30kW).
*
*
*
*
*
*
Above a regulator within 3 feet (91 cm)
horizontally of the vertical center line of the
regulator vent outlet to a maximum vertical
distance of 15 feet (4.5 m).
6 inches (15 cm) for appliances < 10,000
Btuh (3 kW), 12 inches (30 cm) for
appliances > 10,000 Btuh (3kW) and
< 100,000 Btuh (30kW), 36 inches (91 cm)
for appliances > 100,000 Btuh (30kW).
6 feet (1.83 m)
7 feet (2.13 m)+
12 inches (30 cm)
Regulator
vent outlet
US Installations
2
12 inches (30 cm)
6 inches (15 cm) for appliances.< 10,000
Btuh (3 kW), 9 inches (23 cm) for
appliances > 10,000 Btuh (3 kW) and
< 50,000 Btuh (15 kW), 12 inches (30 cm)
for appliances > 50,000 Btuh (15 kW)
*
*
*
*
*
*
*
6 inches (15 cm) for appliances.< 10,000
Btuh (3 kW), 9 inches (23 cm) for
appliances > 10,000 Buth (3 kW) and
< 50,000 Btuh (15 kW), 12 inches (30 cm)
for appliances > 50,000 Btuh (15 kW)
3 feet (91 cm) above if within 10 feet(3 m)
horizontally.
*
*