36" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
Adjusting the minimum gas setting
Since all cooktop burners are of the dual-flame type,
the minimum gas setting must be adjusted for both
the outer and inner rings.
These instructions refer to a single burner. Repeat
the following for each cooktop burner.
1. Push in the burner control knob and light it at the
minimum position
2. Remove the burner control knob, along with the
conical spring and knob ring.
3. Tighten or loosen the highlighted screws to adjust
the minimum flame height.
Conversion to Propane gas (LPG)
WARNING
• Before proceeding with the gas conversion, the
gas supply must be turned off before disconnect-
ing the electrical power.
• A gas leak test should be performed after the gas
conversion has been carried out.
Always provide an adequate gas supply.
This appliance is shipped from the factory for use
with natural gas. Use this kit to convert the appli-
ance for use with propane gas, if necessary. Comply
with the following: Ensure that the range is con-
verted for use with the appropriate gas before using
it.
This appliance is designed to operate at a pressure
of 10" of water column when used with propane gas.
.
When checking if the regulator is working properly,
the inlet pressure must be at least 1" greater than
the operating (manifold) pressure above. When con-
verting for propane gas use, the pressure supplied
to the regulator must be between 11" and 13" of the
water column.
The pressure regulator located in the inlet of the
range manifold must remain in the supply line.
Use a flexible metal appliance connector or rigid
pipe to connect the range to the gas supply. The
connector should have an inside diameter of 1/2"
and be 5 ft (1.5 m) or less in length.
(Exception: Maximum connector length in Massa-
chusetts installations is 3 ft (0.9 m). In Canada, the
connector must be single-wall metal and not longer
than 6 ft (1.8 m).
Save the nozzles removed from the appliance for
future use.
CAUTION
Before proceeding with the gas
conversion, the gas supply must be turned off
before disconnecting the electrical power.
Parts included with the propane gas nozzle kit:
6 x nozzle number 48
4 x nozzle number 91
2 x nozzle number 115
1 x adhesive label for LPG nozzles
1 x nozzles change warning label
1 x sealing gasket
Setting the pressure regulator for Propane Gas
1. Unscrew regulator cap.
2. Unscrew the plastic regulator stem from the regu-
lator cap. Configuration "A" is for Natural Gas.