Indoor Unit Error Display - York Pyrenees Series Service Manual

Split-type room air conditioner
Hide thumbs Also See for Pyrenees Series:
Table of Contents

Advertisement

8.1 Indoor Unit Error Display

Operation
lamp
☆ 1 time
☆ 2 times
☆ 4 times
☆ 5 times
☆ 6 times
☆ 7 times
☆ 1 times
☆ 2 times
☆ 3 times
☆ 4 times
☆ 5 times
☆ 6 times
☆ 1 times
☆ 2 times
☆ 3 times
☆ 5 times
Timer lamp
Display
X
E0
X
E1
X
E3
X
E4
X
E5
X
EC
O
F0
O
F1
O
F2
O
F3
O
F4
O
F5
P0
P1
P2
P4
O(light)
LED STATUS
Indoor unit EEPROM parameter error
Indoor / outdoor units communication error
Indoor fan speed has been out of control
Indoor room temperature sensor T1 open circuit or short
circuit
Evaporator coil temperature sensor T2 open circuit or
short circuit
Refrigerant leakage detection
Overload current protection
Outdoor ambient temperature sensor T4 open circuit or
short circuit
Condenser coil temperature sensor T3 open circuit or
short circuit
Compressor discharge temperature sensor T5 open
circuit or short circuit
Outdoor unit EEPROM parameter error
Outdoor fan speed has been out of control
IPM malfunction or IGBT over-strong current protection
Over voltage or over low voltage protection
High temperature protection of IPM module or
compressor top
Inverter compressor drive error
☆(flash)
X(off)
32