7.4.16 Point check function
Press the LED DISPLAY or LED or MUTE button of the remote controller three times, and then press
the AIR DIRECTION or SWING button three times in ten seconds, the buzzer will keep ring for two
seconds. The air conditioner will enter into the information enquiry status. You can press the LED
DISPLAY or AIR DIRECTION button to check the next or front item's information.
When the AC enter the "information enquiry" status, it will display the code name in 2 seconds, the
details are as follows.
Enquiry information
T1
T2
T3
T4
T2B
TP
TH
Targeted Frequency
Actual Frequency
Indoor fan speed
Outdoor fan speed
EXV opening angle
Compressor continuous running time
Causes of compressor stop.
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
When the AC enter into the information enquiry status, it will display the code value in the next 25s
the details are as follows.
Displaying code
Meaning
T1 temp.
T1
T2 temp.
T2
T3 temp.
T3
T4
T4 temp.
T2B temp.
Tb
TP temp.
TP
TH temp.
TH
Targeted Frequency
FT
Fr
Actual Frequency
Indoor fan speed
IF
OF
Outdoor fan speed
EXV opening angle
LA
Compressor continuous
CT
running time
Causes of compressor
ST
stop.
A0
A1
0
1
2
3
4
5
6
L
A
U
T
29
,