SELF-TESTING NON MAINTAINED EMERGENCY LUMINAIRE WITH WIRELESS COMMUNICATION
TECHNICAL CHARACTERISTICS
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERIES (Pb)
BATTERY PROTECTION
TX/RX FREQUENCY RANGE
TX POWER
INDICATIONS - CONTROLS
CHARGING TIME
MINIMUM AUTONOMOUS DURATION
LIGHT SOURCE
EMERGENCY ILLUMINATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIALS
EXTERNAL DIMENSIONS
TYPICAL WEIGHT
GUARANTEE
GENERAL
These luminaires are used (ta 40 C) where
emergency light is needed. Each luminaire must
be connected permanently to the mains power
supply.
OPERATION DESCRIPTION
When the unit is connected to the mains power
supply (after connecting the battery) the indicator
LAMP FAULT – BATT. FAULT remains OFF
whereas the indicator POWER CHARGE blinks to
indicate that the batteries are charging. When the
batteries are fully charged this indicator will light
permanently. If this indicator does not light then
probably the battery has not been connected. If
the batteries are connected and the indicator does
not light then contact a qualified service technician
for assistance. The charging procedure is
monitored by a microprocessor and is based on a
3 stage cycle thus ensuring a fast and full charge
of the battery. The charge current is supplied by a
high efficiency switch mode power supply which
ensures perfect charging even during the
fluctuations of the mains power supply.
Page 1 from 5
GRL-37/90/WL
POWER-CHARGE indicator, LAMP FAULT–BATT. FAULT indicator, TEST button
EN 61000-3-3, EN 62311, ETSI EN 303 446-1 V1.1.0, ETSI EN 300 220-2 V3.1.1
Thank you for your trust in our products
Olympia Electronics - European manufacturer
o
(for LED MODULE Specifications see page 5)
220-240V AC/50-60Hz
13.3W/14VA
12V/7Ah
From overcharge and deep discharge
868.150-868.450MHz
11dBm
<24 h
90 min.
White Power LEDs
3200lm
IP42
EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2,
5 to 40 C
Up to 95%
Aluminum, ABS/PC, PC
302 x 94 x 350 mm.
4120gr.
3 years (1 year for the battery)
BATTERY CUTOFF
The unit enters this state during the power supply
failure and when the battery has been fully
discharged. In this state the luminaire draws the
least power from the battery in order to prevent
deep discharge.
MANUAL TESTING
Is accomplished by briefly (<1 sec.) pressing the
TEST button. This permits the user to test the good
operation of the luminaire's emergency circuit. The
unit simulates a power failure and the lamps are lit
using the batteries. This manual test does not affect
the automatic test.
DIMMING OPTION
When the luminaire is in emergency mode, with
corresponding pressings of the button, we can
choose the illumination of 100%, 50%, 33% or
turned off, either to increase the autonomy time or
not to consume the battery power unnecessarily.
This option is canceled when the network is
restored.
GRL-37/180/WL
2x12V/7Ah
180 min.
o
6310gr.
923037016_09_001

Advertisement

loading

Summary of Contents for olympia electronics GRL-37/90/WL

  • Page 1 TYPICAL WEIGHT 3 years (1 year for the battery) GUARANTEE Thank you for your trust in our products Olympia Electronics - European manufacturer GENERAL BATTERY CUTOFF These luminaires are used (ta 40 C) where The unit enters this state during the power supply emergency light is needed.
  • Page 2 LAMP TESTING Wireless communication The luminaire tests the good condition of the The WL luminaire models have the ability to lamps in emergency mode and warns the user for communicate over the air with Olympia’s control probable malfunction. If a lamp is found faulty then panels for wireless emergency luminaires.
  • Page 3 Button functionality: Wireless Communication The on-board button has the two following indications (interior) functions: The top LED (LD3-green) indicates the 1. Short press (<2"): a status message will be sent to the Gateway device of the network connection status. wireless network. This LED may blink according to the following patterns: 2.
  • Page 4 INSTALLATION PROCEDURE (For wall mounting only) Mounting holes Fig. 1 Fig.2 Cover retaining screws POWER LAMP FAULT CHARGE BATT. FAULT indicator indicator TEST button 1. Install the included mounting accessories to hook the device from the mounting holes (Fig.1). 2. Unfasten the 4 mounting screws to remove the front plastic cover (Fig.1). 3.
  • Page 5: Warranty

    Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the buyer the transportation cost.

This manual is also suitable for:

Grl-37/180/wl