Three Phase Wiring Diagram - Chamberlain LiftMaster Professional SL585GL Manual

Table of Contents

Advertisement

ON/OFF
SWITCH
L1
L2
3 PHASE
POWER IN
L3
GROUND
WARNING
To protect against fire and electrocution:
• DISCONNECT power BEFORE installing or servicing operator.
• Replace ONLY with fuse of same type and rating.
Fuse: 3AG, 3.2A, 120V, SLO-BLO
R1
24VAC
R2
R3
RADIO
R4
SIGNAL
SAFETY ALARM
(100 db)
J2 PLUG
GL CONTROL BOARD
J2-3
24VAC-IN
J2-4
24VAC-COMMON
J2-5
SOFT OPEN
J2-6
NC
J2-7
"B" LIMIT
J2-1
CONTACTOR B
J2-8
"A" LIMIT
J2-2
CONTACTOR A
J2-9
RPM - IN
J2-10
RPM - SUPPLY
J2-11
RPM GND
J1 PLUG
RADIO COMMAND
J1-1
J1-2
SHADOW
J1-3
+24VDC
J1-4
CLOSE
J1-5
STOP
J1-6
SOFT OPEN
J1-7
HARD OPEN
J1-8
INT. LOOP
J1-9
OBS. OPEN
J1-10
OBS. CLOSE
J1-11
24 VAC-COMMON
J1-12
DC-GND
J1-13
LOCK 1
J1-14
LOCK 1
J1-15
ALARM 1
J1-16
ALARM 1
J4 PLUG
DUAL
1
GATE
2
= TERMINAL BLOCK IN LIMIT SWITCH ENCLOSURE (SL595 ONLY).
NOTES:
1) Transformer primary voltage is the same as the operator line voltage. Secondary 24V 60VA.
2) Wire color: 208V red, 230V orange, 460V purple, 575V gray.
3) Three phase units are equipped with an internal pilot duty thermal overload
device or an external line monitoring device.
T H R E E P H A S E W I R I N G D I A G R A M
(SEE NOTE 3)
OVERLOAD
(BK)
(BK)
(BK)
SEE NOTE 3
(GN)
BLACK (SL595 ORANGE)
PRIMAR
(SEE
NOTE 2)
(BL)
24V Sec.
(SEE NOTE 1)
FUSE
3.2A
(BL)
(TB 2)
AB
(BL)
(BL)
(YE)
(Y/BK)
(BRN)
-
(BK)
+
(RD)
(BL)
(YE)
(GN)
3
L/S B
(PU)
2
NC
COM
(PU)
B
A1
A2
L/S A
1
(OR)
NC COM
A
(OR)
A1
A2
(WH)
RPM
(RD)
SENSOR
(BK)
OPEN
(Y/BK)
(PU)
(PU/WH)
(Y/BK)
(GN)
(Y/BK)
(Y/BK)
STOP
RESET
(BRN)
(OR)
(GN)
(GY)
(OR/BK)
(BK)
(BK)
(BL)
(RD)
(WH)
(RD)
(BK)
A
B
4
3
5
A
B
4
3
1
(BK)
A
2
1
(BK)
B
6
5
(BK)
(BK)
Y
(WH)
(YE)
CD
CLOSE
31
230V CONNECTION
1
(GY) (SL595 GN)
6
(BK)
2
(PU) (SL595 RD)
2
(BK)
3
(YE) (SL595 WH)
460V CONNECTION
1
(GY) (SL595 GN)
(BK)
2
(PU) (SL595 RD)
(BK)
3
(YE) (SL595 WH)
(SEE NOTE 3)
575V CONNECTION
1
(GY) (SL595 GN)
(BK)
2
(PU) (SL595 RD)
(BK)
3
(YE) (SL595 WH)
(SEE NOTE 3)
4
(GN)
6
FREE EXIT
(WH )
7
LOOP HARNESS
(RD)
8
10 PIN - 1,2,3,5
(BK)
9
CAPPED
(BRN)
10
(GY)
4
(GN)
6
INTERRUPT
(WH )
LOOP HARNESS
7
(RD)
8
10 PIN - 1,2,3,5
(BK)
CAPPED
9
(BRN)
10
(GY)
FIELD CONNECTIONS
TB1
(BRN)
(PU)
1
RADIO
(WH)
(P/W)
2
SHADOW
(Y/BK)
3
(Y/BK)
VDC COM
(GN)
4
CLOSE
5
(Y/BK)
STOP/COM
(WH)
6
(BRN)
SOFT OPEN
(OR)
7
HARD OPEN
8
(GN)
INTERRUPT (SAFETY)
9
OPEN
(GY)
EDGE/PHOTOEYE (SAFETY)
10
(OR/BK)
CLOSE
(WH)
11
MASTER / SECOND
12
(RD)
13
(BK)
MAGLOCK
14
(BK)
(BL)
15
24 VAC
16
(YE)
17
(GY)
INTERRUPT LOOP (SAFETY)
18
(BRN)
19
(GY)
EXIT LOOP
(BRN)
20
7
4
230V
8
5
BRAKE
SOLENOID
9
6
7
4
230V
8
5
BRAKE
SOLENOID
9
6
575V
BRAKE
SOLENOID
(SAFETY)
40-32351G

Hide quick links: