Whirlpool HybridCare WED99HEDW Installation Instructions Manual page 9

Heat pump dryer
Hide thumbs Also See for HybridCare WED99HEDW:
Table of Contents

Advertisement

Available languages

Available languages

2.
Attach power supply cord
to strain relief
Put power supply cord through the strain relief. Be sure that
the wire insulation on the power supply cord is inside the
strain relief. The strain relief should have a tight fit with the
dryer cabinet and be in a horizontal position. Do not further
tighten strain relief screws at this point.
If your outlet looks like this:
Power supply cord 4-wire receptacle
(NEMA Type 14-30R):
Go to "4-Wire Power Supply Cord
Connection".
Power supply cord 3-wire receptacle
(NEMA Type 10-30R):
Go to "3-Wire Power Supply Cord
Connection".
4-Wire Power Supply Cord Connection
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire connections.
4-wire receptacle (NEMA
type 14-30R)
Spade terminals with
upturned ends
4-prong plug
Ring terminals
1.
Prepare to connect neutral ground
wire and neutral wire
E
Remove center terminal block screw (B). Remove neutral
ground wire (E) from green external ground conductor screw (A).
2.
Connect neutral ground wire and
neutral wire
Connect neutral ground wire (E) and neutral wire (white or
center) (C) of power supply cord under center terminal block
screw (B). Tighten screw.
3.
Connect ground wire
A
F
Connect ground wire (F) (green or bare) of power supply cord
under green external ground conductor screw (A). Tighten
screw.
B
A
B
E
C