SAFETY LABELS AND DECALS generator generator generator.
Page 8
BASIC GENERATOR FEATURES Fuel Cap: Open the fuel tank cap and fill with Generator Rack: Protects the generator for easy proper amount of gasoline. movement. Air Cleaner : To purify the waste gas. Inverter: Conversion of direct current to alternating current using high frequency bridge circuit.
Page 9
GM3500Xi Low Oil Alarm: Indicates low oil level. Parallel Connectors:To increase AC power output, the connector sockets are used to connect the two Overload Alarm: Indicates that the generator same type generator with special paralleling cords. is overloaded. The connector sockets is only used to the...
Page 10
GM6000XiE Low Oil Alarm: Indicates low oil level. Choke : Pull out to start, press Run. Reset Breaker: If the generator is overloaded, the Overload Alarm: Indicates that the generator reset breaker will trip. The engine will continue to is overloaded. run, but there will be no output from the inverter Power Alarm: Indicates the generator is Unplug the devices and reduce the load.
Page 11
GENMAX Generator generator Carbon Monoxide Specification CO DETECT technology monitors the accumulation of carbon monoxide (CO), a poisonous gas produced by engine exhaust when the generator is running. If CO Sensor detects unsafe elevated levels of CO gas, it automatically shuts off the engine.
Page 13
generator 1. Check the oil level and add oil to the appropriate position.(see Figure 1). Figure 1: The oil plug OIL FILLER CAP OIL FILLER HOLE...
Page 15
GENERATOR GENERATOR, For proper starting and operation of the generator, make sure you review the generator features and their descriptions starting on page 8. Before attempting to start the generator, verify the following: Figure 6: Pull the Recoil Handle out from Generator ·...
Page 16
GENERATOR generator During normal operation, use the following steps to stop your generator: generator 1. Turn the AC circuit breaker to the “OFF” position. 2. Turn the generator switch to the “OFF” position. Turn the fuel valve to the “OFF” position. generator.
Page 17
BEFORE PERFORMING MAINTENANCE ON THE GENERATOR, REVIEW THE SAFETY SECTION STARTING ON PAGE 5, AS WELL AS THE FOLLOWING SAFETY MESSAGES. Avoid accidentally starting the generator during maintenance by removing the spark plug boot from the spark plug. For electric start generator, also disconnect the battery cables from the battery (disconnect the black negative (-) cable first) and place the...
Page 18
Engine oil must always be checked and added when the generator is on a flat, level surface, or an Figure 8. inaccurate reading may result, causing serious engine damage. 1. Always operate or maintain the generator on a flat surface. 2.
Page 19
Drain the oil while the engine is warm to assure complete and rapid draining. 1. Remove the oil dipstick and drain plug to drain the oil. 2. Reinstall the drain plug, then tighten the plug securely. 3. Refill oil and check the oil level. Oil Dipstick 1.
Page 20
(see Figure 11). Figure 11 Figure 12 (see Figure 13) 1. Find the carburetor. 2. Connect the transparent plastic hose and place a suitable container under it to capture the spent fuel (see Figure 12). Figure 13...
Page 21
1. Stop the generator and let it cool for several minutes if running. 2. Move the generator to a flat, level surface. Figure 14 3. Remove the spark plug boot by firmly pulling the plastic spark plug boot handle directly away from the engine (see Figure 14).
Page 22
GENERATOR Proper care should be taken to prepare the inverter for any storage It is important to inspect and clean the generator before every use. 1. Clean the inverter as outlined in Cleaning the Generator. 2. Siphon all gasoline from the fuel tank as best as possible.
Page 23
2. The power cord’s plug connector is not fully engaged in the generator’s outlet. 4. Try connecting a known good appliance to verify the generator is producing electrical power. 1. Generator is out of gasoline. 1. Add gasoline to the generator (see page 14).
Need help?
Do you have a question about the GM3500Xi and is the answer not in the manual?