Sailor RM2042 Technical Manual page 34

Hide thumbs Also See for RM2042:
Table of Contents

Advertisement

3 SERVICE
CHECK OF RECEIVER SENSITIVITY
The receiver sensitivity is controlled by applying a RF-signal to the antenna terminal and then measuring
the output signal-to-noise ratio (SND/N) by means of a voltmeter.
1.
Connect a RF-signal generator to the antenna input and adjust the carrier level to -119 dBm (EMF:
-6 dB/µV). Modulate the carrier with 1 kHz to a peak frequency diviation of 3 kHz.
2.
Connect a voltmeter to the analog switch output, pin 14 at U6-3, for measuring the AC-voltage.
3.
Read the meter deflection by means of the dB scale.
4.
Remove the modulation and control that the output level decrease more than 12 dB.
CHECK OF RECEIVER DISTORTION
The receiver distortion is controlled by applying a RF-signal to the antenna terminal and then measuring
the output distortion by means of a distortion meter.
1.
Connect a RF-signal generator to the antenna input and adjust the carrier level to -30 dBm (EMF:
83 dB/µV). Modulate the carrier with 1 kHz to a peak frequency diviation of 3 kHz.
2.
Connect a distortion meter to the analog switch output, pin 14 at U6-3, for measuring the receiver
distortion.
3.
The measured distortion shall be less than 3%.
CHECK OF DSC CALL SENSITIVITY
The DSC call sensitivity is controlled by modulating a RF-signal generator with a DSC call, which is
generated by the DSC unit it self.
NOTE! To perform this test, it is necessary to change the operation mode of the RM2042 from user to
service mode. This change of operation mode is only allowed for trained technicians and the information
of how to do it, is therefore only included in the DSC-VHF INSTALLATION GUIDE.
1.
Select the balanced TX AF amplifier as interface to the RF-signal generator, by turning the switch
S1-1 at the interface module into the position: 'E'.
2.
Connect the output of the balanced TX AF amplifier to the external modulation input of the RF-
signal generator. Use pin 4 (TX AF+) and pin 8 (TX AF-) in the 9 pole SUB-D connector P2
(connector for VHF tranceiver).
3.
Connect the output of the RF-signal generator to the antenna terminal of the RM2042.
4.
Apply an external modulated carrier with the frequncy 156.525 MHz to the antenna terminal and
adjust the output level to -113 dBm (EMF: 0 dB/µV).
5.
Change the operation mode of the RM2042 from user to service mode.
6.
Select the 'FUNC' menu and then the 'Test' menu. Select 'Dot pattern' by means of the 'left-arrow'
or 'right-arrow', and press the 'NEXT' button.
7.
Adjust the peak diviation at the RF-signal generator to 3400 Hz and press the 'STOP/ENT' button
to terminate the transmission of dot pattern.
8.
Select 'Test call' by means of the 'left-arrow' or 'right-arrow' and press 'NEXT' to start the continous
transmission of a test call to the unit it self.
9.
Now control that the RM2042 is receiving a continous sequence of individual calls.
10.
Terminate this procedure by turning the RM2042 off. Remember to change the operation mode
back to user mode.