WATERPROOF SELF TESTING EMERGENCY LUMINAIRES
TECHNICAL CHARACTERISTICS
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERIES (Ni-Cd)
BATTERY PROTECTION
INDICATIONS
CHARGING TIME
MINIMUM AUTONOMOUS DURATION
ILLUMINATION SOURCE
ILLUMINATION (MAINS / EMERGENCY)
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIALS
EXTERNAL DIMENSIONS
TYPICAL WEIGHT
GUARANTEE
Thank you for purchasing this product of
O l y m p i a E l e c t r o n i c s . A E u r o p e a n
manufacturer.
GENERAL
These luminaires, according to Lloyd's
Register Type Approval System are
s u i t a b l e f o r m a r i n e a n d o f f s h o r e
applications for use in environmental
categories ENV1, ENV2, ENV3 and ENV4,
where ENV1 are controlled environments,
ENV2 are enclosed spaces subject to
temperature, humidity and vibration, ENV3
are enclosed spaces subject to generated
heat from other equipment and ENV4 are
mounted on reciprocating machinery. Each
luminaire must be permanently connected
t o m a i n s p o w e r s u p p l y . I n n o r m a l
operation the led strip lights and the
battery is charging. In case of a mains
power supply failure the luminaire will
light the led strip
emergency mode. When the
power
supply
turns to normal operation.
INSTALLATION
To
install
the
installation instructions on page 3.
OPERATION
Battery charging
The
battery
charging
Page 1 from 2
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3, IEC 60092-306, IEC 60533
automatically in
mains
is
restored the device
luminaire
follow
is
completely
High Quality European based Manufacturers
GR-939/15L/MAR
220-240V AC/50-60Hz
3.5W / 7.5VA
3.6V/1.5Ah
From overcharge and full discharge
Charge, lamp fault, battery fault indication LED
15 white LED's
105lm / 105lm
Bayblend FR3010, transparent polycarbonate
870gr.
3 years (1 year for the battery)
controlled. In this case, is achieved the
perfect battery maintenance , as well as the
elongation of its duration. When the battery
has completely charged, it charges with a
maintenance current.
Battery Cut-off
The luminaire enters in this operation when
the mains power supply fails and battery
has lost its energy. During this operation
the luminaire enters the idle state and
battery consumption is negligible, in order
to be protected from deep discharge.
Manual Test
The manual test can be conducted only if
the main power supply and the battery is
connected. By pressing the TEST/RESET
button briefly (page 3) an operation test is
initiated.
indication LEDs are OFF.
Automatic Test
This test includes all the operations that
provide the manual test and is conducted
automatically every 15 days. In order to be
performed, the main power supply and the
battery should be connected.
Automatic Autonomous Test
the
The
Automatic
conducted and measures the luminaire`s
back up operation. This test is conducted
automatically every six months. In order to
be performed, the main power supply and
GR-939/30L/MAR
5W /8.5VA
3.6V/3Ah
24h
180min
30 white LED's
210lm / 210lm
IP 65
o
5 to 40 C
Up to 95%
363 x 145 x 73 mm
940gr.
During
this
test
Autonomous
923939017_09_003
period
all
Test
is