Testing The Panel's Lamps; Displaying The Panel's Alarm Counter - C-TEC XFP User Manual

Networkable analogue addressable fire alarm control panel
Hide thumbs Also See for XFP:
Table of Contents

Advertisement

XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM PANEL
5
Pressing the
and
information (if applicable) can be viewed by pressing the panel's More Information button. To return
to the main access level 1 menu press the Escape
Display Fault Events
This function is only available if there are active faults on the system. If available, press the
4
Accept
button once and a window similar to the one below will appear:
Zone 1: Ground Floor
There are faults on this zone
5
Pressing the
and
information (if applicable) can be viewed by pressing the panel's More Information button. To return
to the main access level 1 menu press the Escape
Display Disablements
This function is only available when there are active disablements on the system. If available, press the
4
Accept
button once and a window similar to the one below will appear:
1st Zone: 1: Shop floor
On: This Panel: Is Disabled
5
Pressing the
and
information (if applicable) can be viewed by pressing the panel's More Information button. To return
to the main access level 1 menu press the Escape
Display Zones In Test
This function is only available if there are zones being tested. If available, press the Accept
once and a window similar to the one below will appear:
Zone 1: North Stairs
Is On Test
5
Pressing the
and
information (if applicable) can be viewed by pressing the panel's More Information button. To return
to the main access level 1 menu press the Escape

Testing the Panel's Lamps

This function tests the panel's lamps (its LED indicators and display) to ensure they are working correctly.
LAMP TEST?
Display Alarm Counter
When selected, press the Accept
for approximately two seconds and its display will progressively block fill. The panel's internal sounder
(if enabled) will also sound. Upon completion, the panel will return to the main access level 1 menu.
If any of the indicators fail to illuminate or the display does not function correctly, report the fault(s)
to the designated site engineer and make a note of it in the Fire Alarm Log Book (page 21).

Displaying the Panel's Alarm Counter

This function displays the total number of times the panel has been in a fire alarm condition. When
selected, press the Accept
has been in a fire condition since it was installed AND the total number of times it has been in alarm
since its alarm counter was last cleared, for example:
Total Alarms = 12
Alarms since 01/01/05 = 7
To return to the main access level 1 menu press the Escape
XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 13 of 28
6
buttons will scroll the display through all active fire conditions. More detailed
6
buttons will scroll the display through all active faults. More detailed
6
buttons will scroll the display through all active disablements. More detailed
6
buttons will scroll the display through all zones in test mode. More detailed
4
button and all of the panel's LED indicators will illuminate steady
4
button once and the display will show the total number of times the panel
3
button.
3
button.
3
button.
3
button.
AL1
3
or Accept
4
4
button.
button

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xfp502/xXfp502/hXfp501/hXfp501/xXfp501e/hXfp501e/x

Table of Contents