C-TEC XFP User Manual

C-TEC XFP User Manual

Networkable analogue addressable fire alarm control panel
Hide thumbs Also See for XFP:

Advertisement

Quick Links

XFP
NETWORKABLE
ANALOGUE
ADDRESSABLE
FIRE ALARM
CONTROL PANEL
user manual
and log book
Approved Document No. DFU2000510 Rev 1

Advertisement

Table of Contents
loading

Summary of Contents for C-TEC XFP

  • Page 1 NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL user manual and log book Approved Document No. DFU2000510 Rev 1...
  • Page 2: Table Of Contents

    Changing the access level 2 entry code ......................19 System set-up data chart ........................20 Fire alarm log book ........................21-26 Installation certificate ........................27 Commissioning certificate........................28 XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 2 of 28...
  • Page 3: Important Safety Notes

    The manufacturer’s policy is one of continuous improvement and we reserve the right to make changes to product specifications at our discretion and without prior notice. E&OE. XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 3 of 28...
  • Page 4: Introduction

    If you are an authorised engineer, details of access level 3 can be found in the separate Engineering manual. XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 4 of 28...
  • Page 5: User Responsibilities

    British Standards Institute, Customer Services Dept., 389 Chiswick High Road, London, W4 4AL. Tel: +44 (0)20 8996 9001. Web: www.bsi-global.com XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 5 of 28...
  • Page 6: Panel Layout, Indicators And Controls

    To reset the panel: Ensure all alarm conditions are silenced and investigations are complete and press To exit access mode: Remove key press and hold XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 6 of 28...
  • Page 7 Keyswitch control Turning the keyswitch to the armed position (I) gives the user instant access to access level 2 (authorised user level) XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 7 of 28...
  • Page 8: General User Operation

    Whilst calibrating, the display will list the ID code of the device being calibrated, i.e. “L:1 D:154” and the system will not return to normal until the process is complete. XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 8 of 28...
  • Page 9: Fire Conditions

    Details of which outputs have delays running can be viewed by pressing the More Information button. XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 9 of 28...
  • Page 10: 1St-Stage Fire Conditions

    In effect, the 1st-Stage delay on a zone set up for investigation comprises two delays - the initial recognition period (where the user is expected to acknowledge the delay) followed by the investigation period itself. XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 10 of 28...
  • Page 11: Pre-Alarm Conditions

    • Note down the nature of the fault(s) in the Fire Alarm Log Book (pages 21 to 26) • Take appropriate steps to ensure the fault(s) is/are rectified. XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 11 of 28...
  • Page 12: Access Level 1 (General User) Controls And Menu Options

    This function is only available if there are active fire conditions on the system. If available, press the Accept button once and a window similar to the one below will appear: Last Zone: 1:North Stairs :Fire! 1 Zone XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 12 of 28...
  • Page 13: Testing The Panel's Lamps

    Total Alarms = 12 Alarms since 01/01/05 = 7 To return to the main access level 1 menu press the Escape or Accept button. XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 13 of 28...
  • Page 14: Access Level 2 (Authorised User) Controls And Menu Options

    Note that the panel’s Investigate button is only active if an engineer has programmed one or more zones to operate with a 1st-stage investigation delay period (see page 10 for detailed information on this feature). XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 14 of 28...
  • Page 15: Displaying Fire, Fault, Disablement And Test Events

    (assuming that the date programmed into the panel is today’s date). A short confirmation message will confirm the change has been made before the display returns to the main access level 2 menu. XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 15 of 28...
  • Page 16: Changing The Panel's Time And Date

    EVENT HISTORY MENU. Resetting the Event History... Resetting entry 499 XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 16 of 28...
  • Page 17: Disabling Or Enabling Parts Of The System

    Alternatively, to return to the previous menu press the Escape button. XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 17 of 28...
  • Page 18 Accept button to select the desired option. Alternatively, to return to the previous menu press the Escape button. XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 18 of 28...
  • Page 19: Changing The Access Level 2 Entry Code

    BE SURE TO KEEP A RECORD OF THE NEW CODE ON PAGE 20 OF THIS USER MANUAL. XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 19 of 28...
  • Page 20: System Set-Up Data Chart

    We recommend any additional information the user needs to be aware of is detailed below: _________________________________________________________________________________________________________ _________________________________________________________________________________________________________ _________________________________________________________________________________________________________ _________________________________________________________________________________________________________ _________________________________________________________________________________________________________ Completed by ____________________________________ of ______________________________________ on ____ / ____ / ____ XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 20 of 28...
  • Page 21: Fire Alarm Log Book

    OUTSIDE NORMAL HOURS TEL: MANNED CENTRE TEL: MANNED CENTRE CODE: THE NORMAL MAXIMUM ATTENDANCE TIME FOR A MAINTENANCE TECHNICIAN IS: EXPENDABLE COMPONENT REPLACEMENT PERIODS (LIST): XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 21 of 28...
  • Page 22 False alarms and maintenance work should be recorded on page 26. DATE TIME EVENT ZONE DEVICE ACTION REQUIRED COMPLETED INITIALS e.g. test, fire alarm signal, fault XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 22 of 28...
  • Page 23 XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM PANEL DATE TIME EVENT ZONE DEVICE ACTION REQUIRED COMPLETED INITIALS e.g. test, fire alarm signal, fault XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 23 of 28...
  • Page 24 XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM PANEL DATE TIME EVENT ZONE DEVICE ACTION REQUIRED COMPLETED INITIALS e.g. test, fire alarm signal, fault XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 24 of 28...
  • Page 25 XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM PANEL DATE TIME EVENT ZONE DEVICE ACTION REQUIRED COMPLETED INITIALS e.g. test, fire alarm signal, fault XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 25 of 28...
  • Page 26 REQUIRED TICK Maintenance work ZONE DEVICE FURTHER WORK DATE TIME REASONS FOR WORK WORK CARRIED OUT SIGNATURE (WHERE APPLICABLE) (WHERE APPLICABLE) REQUIRED XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 26 of 28...
  • Page 27: Installation Certificate

    Unless supplied by others, the “as fitted” drawings have been supplied to the person responsible for commissioning the system {see Clause 36.2m) of BS5839-1: XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 27 of 28...
  • Page 28: Commissioning Certificate

    _____________ (enter a period of either one week, such period as required by the specification, or such period as recommended by the signatory of this certificate, whichever is the greatest, or delete if not applicable). XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000510 Rev 1 • Page 28 of 28...

This manual is also suitable for:

Xfp502/xXfp502/hXfp501/hXfp501/xXfp501e/hXfp501e/x