Dacor Epicure EG486SCHNG Installation Instructions Manual

Hide thumbs Also See for Epicure EG486SCHNG:

Advertisement

Quick Links

Installation Instructions
Epicure
Cooktop
®
Models: EG366, EG486
THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST
EDITION OF ANSI Z21.1 STANDARD FOR HOUSEHOLD GAS APPLIANCES.
Part No. 102025 Rev. M

Advertisement

Table of Contents
loading

Summary of Contents for Dacor Epicure EG486SCHNG

  • Page 1 Installation Instructions Epicure Cooktop ® Models: EG366, EG486 THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21.1 STANDARD FOR HOUSEHOLD GAS APPLIANCES. Part No. 102025 Rev. M...
  • Page 2: Table Of Contents

    (Propane) ALTITUDE High Altitude Model, 4000 ft.(1219 m) and up No character = Equipped for low altitude operation All specifications are subject to change without notice. Dacor assumes no liability for changes to specifications. © 2007 Dacor, all rights reserved.
  • Page 3: Important Safety Instructions

    From a neighbor’s phone, immediately call the gas ating this or any other appliance. supplier. Follow the gas supplier’s instructions. • Always contact the Dacor Customer Service Team • If you cannot contact the gas supplier, call the fire about problems and conditions that you don’t under- department.
  • Page 4: General Safety Precautions

    Do not allow pot holders to touch hot sur- rear of the cooktop to a combustible material must faces or gas burners. use Dacor backguard model AEB3609, AEB3612, • Do not wear loose or hanging apparel while using (for model EG366) AEB4809, AEB4812 (for model the cooktop.
  • Page 5: Installation Requirements

    Installation Requirements Gas Supply Requirements WARNING • Observe all governing codes and ordinances during • Check your local building codes for the proper method planning and installation. Contact your local building of installation. In the absence of local codes, this department for further information.
  • Page 6: Cabinet And Countertop Layout

    • For installations with a raised vent, install this appliance backguard, use only Dacor model numbers AEB3609, only with the approved Dacor raised vent models listed AEB3612 (EG366), AEB4809 or AEB4812 (EG486). on page 6. * Consult local codes and ordinances for acceptable Gas and Electric Service Location non-combustible materials.
  • Page 7: Cabinet/Cutout Dimensions

    Installation Requirements Cabinet/Cutout Dimensions Cabinet tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted. 1 1/2” (38 mm) 10” (254 mm) to typical countertop combustible side thickness wall Min. both sides 1/2” (13 mm) overhang, both sides 7 3/4” (197 mm) Recommended Cooktop platform gas and electrical...
  • Page 8 Installation Requirements Cabinet/Countertop Dimensions (cont.) Cutout tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted. Gas and electrical connections at right rear section of chassis Gas connection and power cord may be routed through bottom or back of chassis Increase countertop and overhang additional 2 1/2”...
  • Page 9 Control panel raised vent chassis to clear Minimum stiffener countertop Cabinet face height: 30 1/4" Dacor approved (768 mm) raised vent IMPORTANT: See raised vent installation instructions for duct system layout/planning Cabinet/Countertop with Raised Vent - Side View...
  • Page 10: Installation Instructions

    • Crown burner heads (2) provided hold-down bolts and washers provided. Do MAX GRIDDLE) • Knobs (4 standard, 2 not overtighten the bolts. • Dacor Stainless Steel Cleaner • Igniter cleaning brush • WOK ring • Griddle • Hold down bolts/washers (2 sets) •...
  • Page 11: Gas Line Connection

    Installation Instructions Gas Line Connection WARNING • Verify that the gas supply meets specifications before connection. See page 3. • The maximum gas supply pressure to the regulator must never exceed ½ pounds per square inch (psi) or 3.5 kPa. •...
  • Page 12: Burner Component Installation

    Installation Instructions Burner Component Installation WARNING • Never attempt to operate the cooktop with any of the burner parts removed. • Do not attempt to adjust the burner air mixture set- tings. All adjustments are preset at the factory. • Remove the burner parts and grates from their shipping packages.
  • Page 13: Burner Knob Installation

    Installation Instructions Burner Knob Installation CAUTION Installing the cooktop knobs in the wrong position may result in damage to the cooktop griddle. The knobs for the center burners are marked with the maximum griddle settings. There are two (2) different types of knobs supplied with the cooktop.
  • Page 14: Verifying Proper Operation

    Connect the power cord to the electrical outlet. Dacor is not responsible for the cost of correcting problems caused by a faulty installation. Turn on power to the electrical outlet at the circuit breaker or fuse box.
  • Page 15: Installation Checklist

    • Proper installation is the responsibility of the hom- eowner. The importance of proper installation of your Dacor cooktop cannot be overemphasized. □ Is the electrical outlet for the cooktop grounded and located according to these instructions and in accor- dance with all applicable electrical codes? See pages 3 and 4.
  • Page 16: Wiring Diagram

    Wiring Diagram BLACK WHITE...
  • Page 17: Notes

    Notes...
  • Page 18 Notes...
  • Page 20 Dacor ● Phone: (800) 793-0093 ● FAX: (626) 403-3130 ● www.Dacor.com...