Haier HDW15V3S1 User Manual page 28

Table of Contents

Advertisement

Troubleshooting
Error codes on the display
Problem
Acoustic alarm,
display shows
ALARMCODE
The appliance does
Acoustic alarm,
display shows
ALARMCODE
The appliance does
Acoustic alarm,
display shows
ALARMCODE
Leak: The drain
pump
runs permanently!
All other Alarmcodes:
1. Note Alarmcode
2. Contact Service ; refer to CUSTOMER SERVICE
27
Possible cause
Water tap is closed.
Water inlet hose has a kink or
a bend.
In case of aqua-stop system:
water protection is triggered;
the marker (C) is red.
Filter in the water inlet hose
is clogged.
Water inlet is clogged.
Water pressure is too low.
Filters are clogged.
.
The drainage is blocked.
Anti-flood device is on:
• There are water leakages in
the appliance.
• The water inlet valve is
open and blocked.
• The drainage is blocked.
Possible solution
• Open the water tap.
Note: Whenever Error '
solved switch off the appliance
and restart the programm.
Make sure that the position of
the hose is correct.
The hose must be replaced.
Clean the filter at the inlet hose
connections at tap and the rear
of the appliance.
.
Check water flow from tap.
Contact
your
authority.
• Scoop out as much water as
possible.
• Continue
programme
pressing the START/PAUSE
button.
• Scoop out as much water as
possible.
• Make sure that drain water-
connection and piping is
correct and not blocked.
• Continue
programme
pressing the START/PAUSE
button .
If the fault persists, contact
customer care.
1 Close the water tap.
2 Disconnect appliance from
power supply.
3 Contact Service.
' is
local
water
by
by

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hdw15v2

Table of Contents