BARCO PROJECTION SYSTEMS VISION 3200LC R9001189 OWNER'S MANUAL Date : Art. No. : 290997 R5975418A...
Page 4
The use of shielded cables is required to comply within the limits of Part15 of FCC rules and EN55022. BARCO nv/Projection Systems Noordlaan 5 B-8520 Kuurne Belgium Tel : +32/56/368211 Fax : +32/56/351651 E-mail : sales.bps@barco.com Visite Barco at the web : http://www.barco.com Printed in Belgium...
Unpacking & Dimensions Battery installation in the RCU. Note : projector address has to be programmed on the RCU before using the RCU (see chapter 'Controlling'). 310a.DRW...
Page 9
Installation Guidelines INSTALLATION GUIDELINES Installation guidelines * Environment * What about ambient light ? * Which screen type? T p rr à vq u For more information about screens, contact your local screen supplier. * What image size? How big should the image be?
Page 10
Installation Guidelines * Where to install the projector? Inputs and computer video format input compatibility : Definitions of the Abbreviation on drawings Lens type selection. C eiling C D = B - A Optical axis projection lens C D = h e ig h t o f ta b le + s u p p o rtin g fe e t Screen Projector Projector...
Location and Functions of Control LOCATION AND FUNCTION OF CONTROLS Front panel terminology ST!"!ÃPVU 8PHHÃQPSU ST!"!ÃDI 6 V9DPÃPVU 8USG Remote Power switch Loudspeaker Power input IR-Acknowledged : Audio input IR-Received : Input slots : IR receiver Diagnostics code : RS232 IN Projector mode indication...
Location and Functions of Control Control Panel Terminology a. Local keypad (;,7 67$1'%< (17(5 (;,7 6 9 E 7(;7 3$86( (1 7(5 6 9 9 S 6+$531 7,17 %5,*+71 3$ 8 6( )5 ((= 7(;7 T 7 ` &2175$67 3+$6( &2/25 0 8 7 ( 3+$ 6(...
Page 13
Location and Functions of Control Terminology Back light key FREEZ ADJ. ENTER EXIT STBY Control disk '+' and '-' keys PAUSE Mute : '+' and '-' keys Digit buttons RC operating indication Picture controls PHASE Audio controls TEXT Help :...
Connections CONNECTIONS Power (mains) cord connection Fuses &7 5/ ST!"!ÃDI ST!" !ÃPVU 8 P HHÃQPS U 6 V9 DPÃP VU Switching on EXIT STAN D BY EN TER E X I T TEX T PAU S E (17( 5 SH AR PN TINT BR IG H TN 3$86(...
Connections Lamp run time is 750 hours. Operating the lamp longer than 750 hours may damage the projector. Please replace the lamp. Lamp run time 720 h WARNING Lamp run time is 750 hours Warning : Using a lamp for more than 750 hours is dangerous, the Operating the lamp longer than 750 hours may damage lamp could explode.
Connections Video/S-video input module S -VID E O V IDE O A UD IO W D9 @ P T W D9 @ P ÃDI Q V U Ã 6 Ã W Ã D Ã D Ã D 98 27900 98 27 93 0 98 279 10 &75/ S T! "...
Connections RGB analog input module. Ã Ã W Ã D Ã D Ã 9 8 279 00 98 27 91 0 98 27930 &75/ S T!"!ÃDI S T !"!ÃP V U 8 P H H ÃQP S U 6 V 9DPÃP V U 6 I6 GP B ÃDI U@S A6 8 @Ã...
Connections Installation ENTER ADJUSTMENT MODE Select a path from below : RANDOM ACCESS INSTALLATION SERVICE Source 01 ENTER Select with INSTALLATION then <ENTER> <EXIT> to return. INPUT SLOTS CONVERGENCE CONFIGURATION INTERNAL PATTERNS ENTER INPUT SLOTS Select with then <ENTER> <EXIT> to return. 1.
Connections Straps on module level : Ayhvtà ÃÃsyhvtÃv Non-Floating Floating TpÃryrpv T p à à ` T r h h r à p I h y à T p U vyrryÃTp RGB3S/RG3sB input module.
Controlling CONTROLLING IR sensor IR sensor How to use the RCU? S T ! " ! ÃDI ST !"!ÃP VU 8 P H H ÃQ P SU 6V 9 DP ÃP V U 8 U S G Front of projector Rear of projector Ceiling Screen...
Controlling How to display a projector address? ADDRESS PROJECTOR ADDRESS How to program an address into the RCU? ADDRESS Picture controls with direct access. Brightness Control BRIGHTNESS 'brightness' Contrast Control Color Saturation Tint Control Sharpness Control. Phase Control Sound controls with direct access. VOLUME...
Start up of the Adjustment Mode START UP OF THE ADJUSTMENT MODE Adjustment Mode ADJUST ENTER ADJUSTMENT MODE Select a path from below : ENTER EXIT RANDOM ACCESS ADJUST INSTALLATION SERVICE Source 01 Select with then <ENTER> <EXIT> to return. Installation Service Random Access...
Random Access Adjustment Mode RANDOM ACCESS ADJUSTMENT MODE Starting up the Random Access Adjustment Mode ADJUSTMENT MODE Push the control disk up or down to highlight 'Random Access' and then press ENTER. Select a path from below : File service RANDOM ACCESS INSTALLATION SERVICE...
Page 30
Random Access Adjustment Mode Highlight File Service by pushing the control disk up or down and press ENTER to select. The File service menu will be displayed. ENTER displays the File Service menu; RANDOM ACCESS ADJUSTMENT MODE FILE SERVICE EXIT returns to the Path selection menu. PICTURE TUNING ADJUST returns to operational mode.
Page 31
Random Access Adjustment Mode Edit file FILE SERVICE LOAD EDIT ENTER RENAME COPY ENTER EDIT FILE Select with then <ENTER> Filename Resolution <EXIT> to return. ----------------------------------------------------- ntsc .s01 675x240i ntsc .c01 675x240i ntsc .s03 675x240i ----------------------------------------------------- Active file : ntsc.c50 Select with <ENTER>...
Page 32
Random Access Adjustment Mode EDIT FILE OPTIONS Read AMDS Source number Clamp position [leading] Clamp width Field polarity inverted [no] Vertical refresh [sync] Vert. sync polarity [leading] Select with <ENTER> to toggle to change value <EXIT> to return Options Source number Example for clamp position [trailing] Clamp position ENTER...
Random Access Adjustment Mode Rename File ENTER FILE SERVICE ENTER LOAD EDIT RENAME COPY DELETE Select with RENAME FILE then <ENTER> <EXIT> to return. Filename Resolution ----------------------------------------------------- ntsc .s01 675x240i ntsc .c01 675x240i ntsc .s03 675x240i ----------------------------------------------------- Active file : ntsc.c50 Select with <ENTER>...
Page 34
Random Access Adjustment Mode Delete File FILE SERVICE LOAD ENTER EDIT RENAME COPY DELETE OPTIONS ENTER Select with then <ENTER> <EXIT> to return. DELETE FILE Filename Resolution ----------------------------------------------------- ntsc .s01 675x240i ntsc .c01 675x240i ntsc .s03 675x240i ----------------------------------------------------- Active file : ntsc.c50 Select with <ENTER>...
Random Access Adjustment Mode Sync slow/fast PICTURE TUNING Highlight sync by pushing the control disk up or down and press SYNC [SLOW] ENTER to toggle between SLOW and FAST. STILL VIDEO [ON] COLOR BALANCE GAMMA Note : Sync is normally used in the SLOW position. The FAST position is used to compensate for unsteady sync pulses from older video playback equipment.
Random Access Adjustment Mode Audio Tuning RANDOM ACCESS ADJUSTMENT MODE FILE SERVICE PICTURE TUNING AUDIO TUNING GEOMETRY AUDIO TUNING VOLUME BALANCE BASS TREBLE Volume, Balance, Bass and Treble MUTE [OFF] LOCK [INPUT 1] FADE Select with then <ENTER> <EXIT> to return. Mute AUDIO TUNING VOLUME...
Page 37
Random Access Adjustment Mode Geometry RANDOM ACCESS ADJUSTMENT MODE ENTER FILE SERVICE PICTURE TUNING The following adjustment are possible : AUDIO TUNING GEOMETRY - horizontal and vertical image shift. - horizontal and vertical image size Select with - side keystone (only necessary if the projector is mounted under then <ENTER>...
Random Access Adjustment Mode Side keystone GEOMETRY Highlight Side Keystone by pushing the control disk up or down and SHIFT press ENTER to select. SIZE SIDE KEYSTONE BLANKING The side keystone adjustment is used to align the image if the SCALE[1:x] OPTIONS projector is mounted as a non standard projection angle.
Page 39
Random Access Adjustment Mode Adjustment of the blanking on the top of the image BLANKING Adjustment of the blanking on the bottom of the image BOTTOM LEFT Correct by pushing the control disk up or down RIGHT Select with then <ENTER> <EXIT>...
Page 40
Random Access Adjustment Mode Options GEOMETRY SHIFT SIZE SIDE KEYSTONE BLANKING SCALE[1:x] OPTIONS GEOMETRY OPTIONS Use the same side keystone correction for all files ? [YES] <ENTER> to toggle <EXIT> to return 7-12 5975418A BARCOVISION 3200LC 290997...
Installation Mode INSTALLATION MODE Starting up the Installation Mode ADJUSTMENT MODE Select a path from below : ENTER RANDOM ACCESS INSTALLATION ENTER SERVICE EXIT Source 01 Select with then <ENTER> <EXIT> to return. INSTALLATION INPUT SLOTS CONVERGENCE CONFIGURATION INTERNAL PATTERNS Select with then <ENTER>...
Page 42
Installation Mode hole indication line 1 2 0 16 0 Maximum 5 mm right lens shift 2.5 mm 0,2 5 no shift -2.5 mm -0 ,2 5 Maximum 5 mm left lens shift -0,5 Screen Width Maximum 15 mm upwards lens shift 10 mm 5 mm no shift...
PRESET INPUT BALANCE I2C DIAGNOSIS MORE... Select with Select with then <ENTER> then <ENTER> <EXIT> to return. <EXIT> to return. SERVICE BARCO CHANGE PASSWORD CHANGE LANGUAGE DATA 3200 IDENTIFICATION Enter new password ENGLISH CHANGE PASSWORD Proj. address : 001 0000 CHANGE LANGUAGE Soft.
Page 44
Service Mode SERVICE PANEL ADJUSTMENT PRESET INPUT BALANCE RED COARSE IDENTIFICATION WHITE BALANCE CHANGE PASSWORD FIELD FLICKER CHANGE LANGUAGE BLACK LEVEL TOP RESET LAMP RUNTIME BLACK LEVEL BOTTOM LAMP RUNTINE HISTORY GAIN TOP LAMP DRIVE MODE GAIN BOTTOM Select with <ENTER> MORE...
Service Mode Change Password How to enable or disable the password function ? How to change the password ? SERVICE IDENTIFICATION CHANGE PASSWORD CHANGE LANGUAGE RESET LAMP RUNTIME ENTER LAMP RUNTINE HISTORY LAMP DRIVE MODE ENTER MORE... EXIT ADJUST Select with then <ENTER>...
Page 46
Service Mode Reset Lamp Runtime SERVICE ENTER IDENTIFICATION CHANGE PASSWORD CHANGE LANGUAGE RESET LAMP RUNTIME LAMP RUNTINE HISTORY LAMP DRIVE MODE MORE Select with EXIT then <ENTER> <EXIT> to return. WARNING ----------------------------------------------------- RISK OF ELECTRICAL SHOCK _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ RESET LAMP RUN TIME is reserved to qualified...
Service Mode Panel Adjustments SERVICE PANEL ADJUSTMENTS Changing these settings may seriously affect the perform- PRESET INPUT BALANCE ance of the projector. I2C DIAGNOSIS MORE... ENTER WARNING PANEL ADJUSTMENTS is reserved to qualified service personnel <ENTER> to accept <EXIT> to return. Preset Input Balance SERVICE PANEL ADJUSTMENTS...
Lenses LENSES Focusing the lens Lens holder Fastener ring Lens barrel Lens Lens Cleaning Procedure Alternative cleaning procedure for the MD lens, except MD(1.2:1) Cleaning procedure for MD(1.2:1) lens and other MD lenses. lens. FIRST lightly DO NOT DO NOT DO NOT use an aerosol.
Page 52
Lenses Lenses MD(1.2:1) MD(2.3:1) MD(3.4:1) MD(5:1) MD(6:1) MD(7:1) MD(1.7-3:1) MD(3-6:1) Lens formulas to calculate the projector distance.