7. Muting level check
Procedure
Step 1: Tuner [1] (Tuner unit 1) checking
n
The checking procedures describe that the WRU-806A (to
be adjusted) is installed into the Tuner [1] slot on the MB-
806A.
(1) Set the MB-806A as follows;
Front panel (Tuner [1])
Channel setting:
CE62 model; Group 00, 6301 channel (806.125 MHz)
CE69 model; Group 00, 6933 channel (858.125 MHz)
AU66 model; Group00, 6701 channel (799.250 MHz)
Muting: ON (Normal mode)
Rear panel
ATT (ANTENNA A, B) switch: 0 dB
(2) Connect the signal generator to the ANTENNA A IN
connector with DC cut fixture.
(3) Set the signal generator as follows:
Signal generator setting
FREQUENCY(carrier frequency):
CE62 model; 806.125 MHz
CE69 model; 858.125 MHz
AU66 model; 799.250 MHz
RF OUTPUT (Output level): 60 dBuV
MODULATION (Modulation frequency): 1 kHz
DEVIATION (Frequency deviation): ± 5 kHz
(4) Check that RF Indicator LED lights (green) and "NO
TONE" message appears on LCD (Tuner [1]).
(5) Change the RF OUTPUT (output level) of the signal
generator as shown below.
RF OUTPUT (output level): 15 dBuV
(6) Check that RF Indicator LED goes off (green) and
"NO TONE" message disappears on LCD (Tuner [1]).
(7) Increase gradually the RF OUTPUT (output level) of
the signal generator. Check that RF OUTPUT (output
± 5 dB at when RF Indicator
level) is 25 dBuV
EMF
lights (green LED) and "NO TONE" message appears
on LCD (Tuner [1]).
AF
RF
RF indicator lights.
MB-806A (CE)
WRU-806A (CE, AU)
EMF
(= _53 dBm)
EMF
(= _98 dBm)
(8) Connect the signal generator to the ANTENNA B IN
connector with DC cut fixture, and perform the
procedures (3) through (7) above.
(9) Set the channel setting (Tuner [1]) and FREQUENCY
(carrier frequency) of the signal generator as shown 1
and 2 below.
Perform the procedures (1) to (8) above, for each
channel setting (1 and 2).
1 Channel setting:
CE62 model: Group 00, 6217 channel (800.125 MHz)
CE69 model: Group 00, 6901 channel (854.125 MHz)
AU66 model: Group 00, 6601 channel (792.250 MHz)
Signal generator setting:
FREQUENCY (Carrier frequency)
CE62 model: 800.125 MHz
CE69 model: 854.125 MHz
AU66 model: 792.250 MHz
2 Channel setting:
CE62 model: Group 00, 6363 channel (813.875 MHz)
CE69 model: Group 00, 6964 channel (862.000 MHz)
AU66 model: Group 00, 6751 channel (805.500 MHz)
Signal generator setting:
FREQUENCY (Carrier frequency):
CE62 model: 813.875 MHz
CE69 model: 862.000 MHz
AU66 model: 805.500 MHz
Step 2: Tuner [2] to Tuner [6] checking
When the WRU-806A Tuner Unit is installed in the Tuner
[2] (Tuner unit 2) to Tuner [6] (Tuner unit 6) of the MB-
806A, perform the adjustments from procedures (1) to (4)
of "Step 1. Tuner [1] (Tuner unit 1) checking" on the
respective tuner units that are installed in the MB-806A.
When performing the above described checking change the
following details as shown below, of the "Step 1. Tuner
[1] (Tuner unit 1) checking".
Tuner [1]→ Tuner [2], [3], [4], [5], and [6]
3-15