If you are installing for wireless interconnect function, and have not yet setup your wireless alarm network, do
not connect your wireless unit to the AC quick connect harness or mounting bracket yet. Go back to Section
9: ACTIVATION AND WIRELESS ALARM NETWORK. If you are not using the wireless interconnect function, or if you have
finished wireless alarm setup, then proceed with the following three steps.
Plug the AC QUICK CONNECTOR into the wiring harness attached to the unit, making sure that the locks on the
connector snap into place. Then push the excess wire back into the electrical box through the hole in the center of
the mounting bracket.
Install the alarm fully on the mounting bracket by rotating the alarm in a clockwise direction.
mount to the bracket in 4 positions (every 90 degrees).
automatically activate the battery backup.
Turn on the AC power. The green AC Power On Indicator should be lit when the alarm is operating from AC power.
note:
Wireless units will emit a series of LED blinks, tones, and voices as the unit(s) search for a wireless alarm
network. If you are intending to use wireless units without the wireless function, ignore these notifications, and
the wireless function will turn off in about 15 minutes. You can turn the wireless function on again at a later date if
desired. See Section 9.2.
note:
Attaching AC power first, without rotating the alarm onto the mounting bracket, will result in a low battery
trouble condition chirp (see Troubleshooting Guide). You need to activate the battery to eliminate the low battery
trouble condition chirps. Attach unit to mounting bracket very soon after applying AC power to avoid false low
battery notification.
note:
The battery activation is a one-time feature. After activation, the battery cannot be turned off, and can
only be discharged at the end of unit life. If the alarm is removed from the mounting plate, the backup battery will
remain active. See Permanently Disable Alarm / Discharge Battery section.
The alarm is now activated! After installation / activation, test your alarm as described in Operation and Testing section.
22
note:
Installing the alarm on the mounting bracket will
note:
The alarm will