Kidde P4010ACSCO-W User Manual page 21

Smoke and carbon monoxide alarm. combination photoelectric smoke & carbon monoxide alarm with voice and hardwire/wireless interconnect
Hide thumbs Also See for P4010ACSCO-W:
Table of Contents

Advertisement

note:
Use standard UL Listed household wire (as required by local codes) available at all electrical supply
stores and most hardware stores.
FUSE OR CIRCUIT BREAKER
BLACK
WHITE
First
Alarm
Wires on alarm harness: Connected to:
Black: Hot side of AC line
White: Neutral side of AC line
note:
AC power should be turned off at this stage.
After selecting the proper location for your Alarm, and wiring the AC
QUICK CONNECT harness as described in the WIRING INSTRUCTIONS,
attach the mounting bracket to the electrical box. To ensure aesthetic
alignment of the alarm with the hallway, or wall, the "A" line on the
mounting bracket must be parallel with the hallway when ceiling mount-
ed, or horizontal when wall mounted.
Pull the AC QUICK CONNECTOR through the center hole in the mounting
bracket and secure the bracket, making sure that the mounting screws are
positioned in the small ends of the keyholes before tightening the screws.
RED
BLACK
WHITE
Additional
Alarm
Red: Interconnect lines (red wires) of other
units in the multiple station set-up
Figure 10-A, Interconnect Wiring Diagram
RED
Kidde Relay Module
SM120X, CO120X
or both
Optional
Accessory
AC connector
shipped with
product
BLACK
WHITE
Additional
Alarm
AC connector
Figure 10-B
RED
Existing Kidde
AC Connector
(either connector
can be used for
this model)
21