Re-assembly: Select Option A, B, or C
A. NO VALVE OPTION (Styles 2, 4, 14)
Install Bumping Spring (8) in the bottom cavity; secure it by screwing in Plug Seal (3)
until it is flush with Bracket (5). Proceed to steps 1-3.
B. VALVE OPTION (Styles 2,4)
Install Bumping Spring (8) in the bottom cavity; while squeezing the spring with appropri-
ate flat stick insert Valve Cartridge (11), tighten it. Screw in bottom Plug Seal (3) until it is
flush with Bracket (5). Proceed to steps 1-3.
C. VALVE OPTION (Style 14)
Insert the plastic Y-shape Float Stop (14) from the wide bore using an appropriate non-
metal stick; push the stop all the way down the bore. Screw in Valve Cartridge (13), and
reinstall Knob (15). Screw in bottom Plug Seal (3) until it is flush with Bracket (5).
Proceed to steps 1-3.
STEPS: 1. Insert Float (6),
2. Insert Bumping Spring (8) into the top cavity; secure it by screwing in Plug
Seal (3) until it is flush with Bracket (5).
3. Shake the meter making sure the ball is floating free without restrictions.