Download Print this page

Factory Settings; Brew Time - Grindmaster B-3WL Operator's Manual

Amw b-series
Hide thumbs Also See for B-3WL:

Advertisement

Page 2

FACTORY SETTINGS

• Tank temperature is set at 200 degrees F.
• Brew time is pre-set at 2:20. (Volume/time to be set on-site)
• Pulse Brew is set for 1 pulse, 20 sec on, 20 sec off.
• Warmer Energy Savings mode is set for 60-minutes. ("OFF" for models without warmers)
• Low Temp / No Brew option is set to "OFF" or disabled.
• Pour over setting override is set to "no" or plumb in.
• Settings lock-out jumper on controller is set in "unlock" position.
ADJUSTMENTS:
Refer to B-Series Programming Chart on page 5.
NOTE: Set each dispense head individually.
Tank Temperature:
Left display controls this.
Note: On two head models, tank temperature must be set to the same setting on both heads in order for the unit to operate properly.
• Press-and-hold both "up" and "down" arrows for 5 seconds.
• The display will indicate either "d F" or "d C". (Fahrenheit or Celsius)
• Press up or down arrow to change from one scale to the other.
• Press "BREW" button to accept and proceed to the next setting.
• The display will read temperature value in the scale previously selected.
• Press up or down arrow to change temperature value.
• Press "BREW" button to accept and proceed to the next setting.

Brew Time:

• The display will read "br ". (brew time)
• Press "BREW" button to proceed to the next setting.
• The display will read the set brew time in minutes and seconds. (ex: 2.20)
• Press up or down arrow to change time value.
• Press "BREW" button to accept and proceed to the next setting.
Pulse Brewing Mode:
• The display will read "P-b". (pulse brew)
• Press "BREW" button to proceed to the next setting.
• The display will read "OFF" - "1"- "6".
• Press up or down arrow to change number of pulses.
• Press "BREW" button to proceed to the next setting.
• The display will read "0.05" - "0.30".
• Press up or down arrow to change pulse-on time for each pulse in seconds.
• Press "BREW" button to proceed to next setting.
• The display will read "0.05" - "0.30".
• Press up or down arrow to change pulse-off time for each pulse.
• Press "BREW" button to accept and proceed to the next setting.
Energy Savings Mode (Warmer shut-off):
• The display will read "E-S". (energy savings)
• Press "BREW" button to proceed to the next setting.
• The display will read "Off" - "10" - "240" in multiples of 10.
• Press up or down arrow to change time value in minutes. Must be "OFF" for models without warmers.
• Press "BREW" button to accept and proceed to the next setting.
Low Temp/No Brew Mode:
• The display will read "Ltn" (Low Temp/No Brew).
• Press "BREW" button to proceed to the next setting.
• Press up or down arrow to change to "ON" or "OFF".
• Press "BREW" to accept and proceed to the next setting.
(for each dispense head)
B-SERIES

Advertisement

loading

This manual is also suitable for:

B-3wrB-dgpB-idB-sapB-6B-3 ... Show all