Midea ML2EC10SABS Service Manual page 14

Table of Contents

Advertisement

COMPONENTS
FUSE
HEATER ELEMENT
(Wire leads removed.)
THERMAL CUT-OUT
TEST PROCEDURE
Check for continuity of the fuse with an
multi-meter.
NOTE: If the fuse is blown, check the primary, the secondary, and the monitor switches,
H.V.D. and H.V.C. before replacing the fuse.
If the fuse is blown by improper switch operation replace the defective switch and the
fuse at the same time. Replace just the fuse if the switches operate normally.
Measure the resistance.
(Multi-meter scale: Rx1)
Measure the resistance with 500V-100M ohm
insulation resistance meter.
NOTE: Make sure heater is fully cooled when tested.
12
RESULTS
Normal
Abnormal
Normal:
*Grill heater
Approx. 38 ohm
(at 20 ~ 30°C)
Normal: more than 0.5 Mohm
Below specified
Above
temperature
temperature
specified