Other Parameters - Moxa Technologies NPort 5000 Series User Manual

Hide thumbs Also See for NPort 5000 Series:
Table of Contents

Advertisement

Other Parameters

NPort 5000 Series User Manual
Force transmit
Setting Options: 0 to 65535 ms
Default: 0 ms
Description: Controls data packing by the amount of time that
elapses between bits of data. As serial data is received, it
accumulates in the device port's buffer. If serial data is not received
for the specified amount of time, the data that is currently in the
buffer is packed for network transmission. A setting of 0 means that
data in the buffer will not be automatically packed when additional
data is not received from the device. When using this field, make
sure Inactivity time is disabled or set to a larger value. Otherwise,
the connection may be closed before the data in the buffer can be
transmitted.
Local TCP port
Setting Options: 1 to 65535
Default: 4001 for port 1, 4002 for port 2, etc.
Description: Specifies the TCP port number for communicating with
the attached device. Socket applications will need to use this port
number to refer to the device. For Pair Connection modes, this field
specifies the slave's port number, and the same value must be used
for the master's Destination IP parameter.
Command port
Setting Options: 1 to 65535
Default: 966
Description: Specifies the TCP port number for Moxa IP-Serial
Library commands. You do not need to reference this port number
in your application when using the Moxa IP-Serial Library, since the
library automatically obtains the number from the device server.
Only change this setting if there is a port number conflict with
another application or device.
Destination IP address
Setting Options: N/A
Default: none
Description: Specifies the IP address for the slave end of a pair
connection.
Destination IP address 1 through 4
Setting Options: N/A
Default: none
Description: Specifies the network host(s) that will access the
device. Serial data will be transmitted to every address listed, and
network data will be sent to the device on a first-in-first-out basis.