Electrical Connection
• Connect the hood to the mains
through a two-pole switch having a
contact gap of at least 3 mm.
• Remove the grease filters (see para-
graph Maintenance) being sure that
the connector of the feeding cable is
correctly inserted in the socket placed
on the side of the fan.
Chimney assembly
Upper Chimney
• Slightly widen the two sides of the
upper flue and hook them behind the
brackets 7.2.1, making sure that they
are well seated.
• Secure the sides to the brackets by
using the 4 screws 12c (2,9 x 9,5)
supplied.
• Make sure that the outlet of the exten-
sions pieces is aligned with the chim-
ney outlets.
Lower Chimney
• Slightly widen the two sides of the flue
and hook them between the upper
flue and the wall,
making sure that they are well seat-
ed.
• Fix the lower part laterally to the hood
body by using the 2 screws 12c (2,9 x
9,5) supplied.