    GUARANTEE CONDITIONS INSTALLATION INSTRUCTIONS ELECTRICAL CONNECTIONS INSTALLING THE COOKER HOOD Welcome to the world of Electrolux Thank you for choosing a fi rst class product from Electrolux, which hopefully will provide you with lots of pleasure in the future. The Electrolux...
  • Page 4: Important Safety Information

    Refer to your local • If the room where the hood is to be used Electrolux Service Force Centre. Always contains a fuel burning appliance such as insist on genuine spare parts. a central heating boiler then its fl ue must be of the room sealed or balanced fl...
  • Page 5: Your Appliance

    5 YOUR APPLIANCE AND OPERATING INSTRUCTIONS YOUR APPLIANCE...
  • Page 6: Operating Instructions

    6 electrolux YOUR APPLIANCE AND OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS The cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam. The hood can be switched on pushing directly onto the requested speed without fi rstly having to select 0/1 button.
  • Page 7 7 To Operate Select the required fan speed and light if required. Recirculation recirculation mode contaminated air enters the cooker hood through the grease fi lters. The air is cleaned by passing through the charcoal fi lters before being passed back into the kitchen through the grilles in either side of the chimney stack.
  • Page 8: Maintenance And Cleaning

    8 electrolux MAINTENANCE AND CLEANING MAINTENANCE AND CLEANING Before carrying out any maintenance or cleaning isolate the cooker hood from the mains supply. The cooker hood must be kept clean, as a build up of grease or fat can be a fi...
  • Page 9 9 MAINTENANCE AND CLEANING Before carrying out any maintenance The fi lter is not washable and cannot or cleaning isolate the cooker hood be regenerated. It must be replaced from the mains supply. when led S1 fl ashes or at least every 4 months.
  • Page 10 10 electrolux MAINTENANCE AND CLEANING Changing the halogen light • Remove the snap-on lamp cover by levering it from under the metal ring, supporting it with one hand. • Remove the halogen lamp from the lamp holder by pulling gently.
  • Page 11: Something Not Working

    11 SOMETHING NOT WORKING SOMETHING NOT WORKING If, having followed these instructions carefully, your cooker hood fails to work properly please carry out the following checks. Solution Symptom • Check the hood is connected to the The cooker hood will not start electricity supply.
  • Page 12: Guarantee/Customer Service

    12 electrolux GUARANTEE/CUSTOMER SERVICE GUARANTEE/CUSTOMER SERVICE Standard guarantee conditions the United Kingdom. We, Electrolux, undertake that if within • Appliances found to be in use within commercial environment, plus 12 months of the date of the purchase those which are subject to rental this Electrolux appliance or any part agreements.
  • Page 13: Guarantee Conditions

    • The appliance is installed and used accordance with instructions issued by Electrolux and is only used within the home, i.e. is not used for commercial purposes. • The appliance installed accordance...
  • Page 14 +41 62 88 99 111 Industriestrasse 10, CH-5506 Mägenwil Slovenija +38 61 24 25 731 Tržaška 132, 1000 Ljubljana Electrolux Slovakia s.r.o., Electrolux Domáce spotrebiče SK, Slovensko +421 2 43 33 43 22 Seberíniho 1, 821 03 Bratislava Suomi +35 8 26 22 33 00 Konepajanranta 4, 28100 Pori Electrolux Service, S:t Göransgatan 143, S-105 45...
  • Page 15: Installation Instructions

    15 INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS It is dangerous to alter the specifi cations or attempt to modify this product in any way. Technical Information DIMENSIONS HEIGHT OF CANOPY: 70mm HEIGHT OF CHIMNEY: (UPPER SECTION) 465mm (LOWER SECTION) 740mm WIDTH OF CANOPY :...
  • Page 16: Electrical Connections

    16 electrolux ELECTRICAL CONNECTIONS ELECTRICAL CONNECTIONS DOUBLE INSULATED DO NOT EARTH Electrical Requirements This appliance is fi tted with a 2 core Any permanent electrical installation mains cable and must be permanently must comply with the latest I.E.E. connected to the electricity supply...
  • Page 17: Installing The Cooker Hood

    17 INSTALLING THE COOKER HOOD INSTALLING THE COOKER HOOD Please ensure that when the appliance is installed it is easily accessible to an engineer in the event of a breakdown. All installations must comply with the local authorities requirements for the discharge of exhaust air.
  • Page 18 18 electrolux INSTALLING THE COOKER HOOD The cooker hood is made up of the following components: Ref Qty Product Components Hood body, complete with controls, lighting, fan and fi lters. Telescopic Chimney comprising: Upper section Lower section ø150-120 Ducting spigot ø120-125 Ducting fl...
  • Page 19 19 INSTALLING THE COOKER HOOD Clearance Height When installed between adjoining wall The cooker hood is designed to be cabinets, the wall cabinets must not fi tted over a cooking appliance at the overhang the hob and the distance...
  • Page 20 20 electrolux INSTALLING THE COOKER HOOD • Repeat this operation on the other Fitting the Wall Brackets side. Wall marking: • Drill ø 8 mm holes at all the centre • Draw a vertical line on the supporting points marked.
  • Page 21 21 INSTALLING THE COOKER HOOD Fitting the Hood Body • Before starting to fi x the hood body, tighten the two screws Vr located on the top of the hood body. • Hook the hood body onto the two 4.2x44.4mm screws item 12a.
  • Page 22 22 electrolux INSTALLING THE COOKER HOOD Recirculation The cooker hood is supplied specifi ed for use in the recirculation mode, with the charcoal fi lter fi tted. In the recirculation mode contaminated air is passed through the charcoal fi lter to be purifi...
  • Page 23 23 INSTALLING THE COOKER HOOD Extraction The charcoal fi lter is not required in this mode and should be removed. Ducting The ducting used must be Ø150mm (6ins), or Ø125mm (5ins) in diameter. If possible duct through the wall immediately above the hood body.
  • Page 24 24 electrolux INSTALLING THE COOKER HOOD Electrical Connection and Working Test Before fi tting the chimney to the canopy make the electrical connection as described in the section titled “ELECTRICAL CONNECTION”. When the electrical connection has been made, test the three speed fan and worktop illumination.