Fault Codes - GE GeoSpring GEH50DFEJS Owner's Manual

Hybrid electric residential water heaters
Table of Contents

Advertisement

Fault Codes

Fault Code
Displayed
Condition
F-C
Evaporator Not Frost Free. Probable refrigerant leak.
F-D
Superheat Too Low. Possible refrigerant leak.
F-E
Discharge Temperature Above Limit.
Possible refrigerant leak.
F-F
Probable refrigerant leak.
F-G
T5 Ambient Temperature Check
F-I
Refrigerant Leak Test. Probable refrigerant leak.
F-J
Concurrent Load High Current
F-L
Evaporator Not Defrosting
F2
T2 Tank Temperature Sensor Failure
F3
Compressor Failure
F4
Fan Failure
F5
T3a Sensor (Evap inlet temperature) Failure
F6
T3b Sensor (Evap outlet temperature) Failure
F7
T4 Sensor (Compressor outlet) Failure
F8
T5 Sensor (ambient temperature) Failure
F9
Lower Heating Element Failure
F10
Upper Heating Element Failure
F11
Dry Tank Fault
bAd linE
The voltage is too low at power-up
(F12)
F13
Stuck Key Fault
Dirty Filter
Filter is dirty. If fault repeats after clearing, probable refriger-
(F14)
ant leak.
F15
DataFlash Fault
F16*
Anode Rod Depleted
F17*
Empty Tank or Anode Rod Wired Incorrectly
F18
Current Tansformer Wired Incorrectly
F19
Low Line Voltage
F20
Condensate Drain Pan Port Clogged
F21
Application Update Failure
F22
Parametric Data Updated Failure
F23
Micro A/D Failure
* Some Models
**Service technicians should use TB01-16 to check for leaks.
49-50300-2
Action
Call service**
Call service**
Call service**
Call service**
Technician service data
Call service**
Call service
Call service
Call service
Call service
Call service
Call service
Call service
Call service
Call service
Call service
Call service
See page 15
See page 15
Call service
See page 10
Call service
Call service, see page 11
Call service
Call service
Technician service data
See page 10
Call service
Call service
Call service
21