TECH SHEET - DO NOT DISCARD
Power button controls
Status indicators at right.
Rotating knob turns
indicators on or off.
"Less Time" button
"More Time" button
turns the right digit of
turns the left digit of
the display on or off.
the display on or off.
Figure 1. Console Diagnostics.
DIAGNOSTIC: Motor, Heater, and Console ID
Close the door. Press the Start button. The motor and heater will turn
on, and the display will show one of the following console IDs:
C0
C1
C2
C3
C4
C5
C6, C7
,
,
,
,
,
,
,
If none of the Console IDs above are displayed, replace the
user interface assembly. See Accessing & Removing the
Electronic Assemblies, page 11.
If the motor does not turn on, go to TEST #3, page 7.
If no heat is detected, go to TEST #4, page 8.
DIAGNOSTIC: Displaying Inlet Air Flow
Used to display the airflow value at the inlet of the heater box being
measured by the machine control.
After all saved fault codes have been displayed, press the Wrinkle
Shield button to activate airflow detection. A 30 or 50 second
countdown timer will start and the dryer will turn on.
If the dryer is cold, the countdown will start at 50 seconds.
NOTE: If the dryer is extremely cold (less than 40°F [4.4°C]) the
airflow may not be detected properly, and "--" will be displayed.
If the dryer is hot, the countdown timer will start at 30 seconds
(cool down period) followed by an additional 50 second
countdown.
A Dryness modifier LED will also be illuminated to indicate the airflow
range corresponding to the number displayed.
The More LED will be illuminated for airflow readings above 40 cfm.
The Normal LED will be illuminated for airflow readings between
29 and 40 cfm.
The Less LED will be illuminated for airflow readings less than
29 cfm.
If airflow value is low, check to make sure the lint screen is
clean, the door seal is in place and the vent is not obstructed.
FOR SERVICE TECHNICIAN'S USE ONLY
Dryness button controls
all indicators above button.
C8
C9
, or
.
Temperature button controls
Each button controls
all indicators above button.
its own indicator.
DIAGNOSTIC: Displaying Line Voltage
Used to display the line voltage currently being measured by the
machine control:
After all saved fault codes have been displayed, press the Cycle
Signal button. The last 2 digits of the voltage value will be displayed
on the dual 7-segment display.
A Dryness modifier LED will also be illuminated to indicate the
voltage range corresponding to the number displayed. The Dryness
LEDs relate to specific voltage ranges as follows:
The More LED will be illuminated for high voltage readings (above
260 VAC).
The Normal LED will be illuminated for normal voltage readings
(200-260 VAC).
The Less LED will be illuminated for low voltage readings (below
200 VAC).
If the line voltage is not seen on L2 the display will flash
Go to TEST #1, page 6.
DEACTIVATING THE DIAGNOSTIC TEST MODE
Press the Pause/Cancel button twice to exit diagnostics.
ACTIVATING THE MANUAL LOAD TEST
1. Be sure the dryer is in standby mode (plugged in with all
indicators off, or with only the Clothes Dry indicator on).
2. Select any one button (except Pause/Cancel) and follow the steps
below, using the same button (remember the button):
Press/
Release
Press/
hold 2-5
for 2-5
hold 2-5
seconds
seconds
seconds
88
flashes momentarily, the motor starts right away, and the Heavy
Duty LED flashes (this step starts the Manual Load sequence):
1. Turn on motor.
Flash "Heavy Duty" LED.
Start button turns on dryer.
Turns off all indicators and
exits diagnostic mode.
Release
Press/
Release
for 2-5
hold 2-5
for 2-5
seconds
seconds
seconds
PART NO. W10054150
PAGE 2
L2
.
Press/
hold 2-5
seconds

Hide quick links: