Summary Of Current Limit Adjustments - GE IC3645SR3R404R2 Installation And Operation Manual

Table of Contents

Advertisement

ADJUSTABLE FEATURES
SX TRANSISTOR CONTROLS
This FIELD WEAKENING START takes effect when the
Mode 2 settings are called for by the Interactive Dash
Display.
FUNCTION 54
MODE 2 MINIMUM FIELD CURRENT
(Push CONT 7)
Same as Function 50.
This MINIMUM FIELD CURRENT takes effect when the
Mode 2 settings are called for by the Interactive Dash
Display.
FUNCTION 55
MODE 2 RATIO
(Push CONT 8)
Same as Function 51.
This RATIO takes effect when the Mode 2 settings are
called for by the Interactive Dash Display.
FUNCTION 56
MODE 3 ARMATURE CONTROLLED
ACCELERATION AND 1A TIME
(Push CONT 9)
Same as Function 48.
This C/A AND 1A TIME takes effect when the Mode 3
settings are called for by the Interactive Dash Display.
FUNCTION 57
MODE 3 FIELD WEAKENING START
(Push CONT 10)
Same as Function 49.
This FIELD WEAKENING START takes effect when the
Mode 3 settings are called for by the Interactive Dash
Display.
FUNCTION 58
MODE 3 MINIMUM FIELD CURRENT
(Push CONT 11)
Same as Function 50.
This MINIMUM FIELD CURRENT takes effect when the
Mode 3 settings are called for by the Interactive Dash
Display.
FUNCTION 59
MODE 3 RATIO
(Push CONT 12)
Section 6.5 Summary of Current Limit Adjustments
Same as Function 51.
This RATIO takes effect when the Mode 3 settings are
called for by the Interactive Dash Display.
FUNCTION 60
MODE 4 ARMATURE CONTROLLED
ACCELERATION AND 1A TIME
(Push CONT 13)
Same as Function 48.
This C/A AND 1A TIME takes effect when the Mode 4
settings are called for by the Interactive Dash Display.
FUNCTION 61
MODE 4 FIELD WEAKENING START
(Push CONT 14)
Same as Function 49.
This FIELD WEAKENING START takes effect when the
Mode 4 settings are called for by the Interactive Dash
Display.
FUNCTION 62
MODE 4 MINIMUM FIELD CURRENT
(Push CONT 15)
Same as Function 50.
This MINIMUM FIELD CURRENT takes effect when the
Mode 4 settings are called for by the Interactive Dash
Display.
FUNCTION 63
MODE 4 RATIO
(Push CONT 16)
Same as Function 51.
This RATIO takes effect when the Mode 4 settings are
called for by the Interactive Dash Display.
48