Page 2
IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This symbol points out important safety instructions which, if not followed, could endanger the personal safety and/or property of yourself and others. Read and follow all instructions in this manual before attempting to operate your machine. Failure to comply with these instructions may result in personal injury.
Page 3
Service • Use proper containers when draining the oil. Do not use food or beverage containers that may mislead someone into drinking from them. Properly dispose of the containers, or store in a safe place immediately following the draining of the oil. •...
Section 1- Setting up the machine Before choosing the site for the machine, please consider that you will also need room for packaged and non-packaged products apart from the space needed for the machine itself. Keep in mind that the machine must not be set up upon uneven ground. Especially with mobile models, the weight of the pump might then cause warping of the machine.
Section 2- Operation 2.1. Working principles A vacuum packaging cycle is made of 3 stages. First the vacuum is made, the air is completly taken out of the chamber and from bag containing the product. (See figure 1). Then it is possible to inject neutral gas from the nozzles, if the product is delicate. Finally, a mechanism pushes the sealing bar to the rubber support to seal the bag.
2.2.2. Top and bottom sealing (option) When sealing aluminium laminate bags (especially bags for e.g. coffee) it is imperative to have an upper and a lower sealing bar. 2.2.3. Electrical bag cut (option) This option is used to obtain a package that the excess bagtail is cut off close to the seal (cannot be used with top and bottom sealing).
2.3.2.3. Select operating mode When executing the "select operating mode" function, which is available only for the automatic units, the actual selection is blinking to point out the acquisition mode. Use key "SELECT" to get through the operating modes, which are automatic, semi-automatic and manual;...
2.4.3. Vacuum plus time setting For a selected program set the vacuum plus time, in seconds; the validation is automatically performed following the second digit entry (the new vacuum plus time is blinking). In a middle of an acquisition, use key "ENTER" to validate the vacuum plus time and key "ESC"...
During cycle execution, use key "1" to abort the vacuum sequence and execute the following sequence, which is gas flush or sealing, and key "ENTER" to accede and modify the program; the parameters become valid only for the following vacuum cycles. 2.6.
Section 4- Cleaning For hygenic cleanliness, it is imperative to clean chamber and spacers daily. Also clean the lid rubber to assure tight seat of the lid. Cleaning instructions for gas injection nozzles: Periodically on a regular basis the gas injection nozzles must be removed with the connection tube and soaked in a food grade soap and water solution, then dried and re-installed.
5.2.2. No leakage in the bag Bag is too large, therefore the surplus of air remains visible (there is surplus of air in 0.4% of the bag volume in each bag). Use bags of suitable size. Vacuum level is too low: Pressure bar is jammed and closes opening of bag during evacuation.
5.3.3. Permanent sealing current Contactor is jammed check sealing transformer for damage through overload. 5.3.4. Seal does not stick Insufficient layer of polyethylene (inferior quality of bags). Seal area extremely contaminated by fat or meat juice. Use filling aid. Sealing temperature is too low (when using very thick films). Caution: Do not increase sealing time more than really necessary;...
Page 16
Check switch-point of micro switch, adjust if necessary. Check evacuation hose for damage (contraction of diameter, or abrasions). Check vacuum connections for tightness. Check oil in pump (oil level in view glass; add if necessary. Regular change of oil - necessity indicated by change of color).
Page 41
31.5 VUE A REF. THIS SIDE OF SEAL BAR TO FIT FLUSH W/SUPPORT -TWIN SEAL OPTION- MACHINE DEPT. TOL. METRIC INCH SIPROMAC 600A & 620A USINAGE ± 0.1 ± 0.004" TOLERIE ± 0.5 ± 0.020" SOUDAGE ± 0. 5 ± 0.020"...
Page 42
ALLOW TO MOVE FREELY INSTALLER CONTRE L'ENCOCHE DE L'ITEM #9 4 INSTALL AGAINST NOTCH OF ITEM #9 -TWIN SEAL OPTION- MACHINE DEPT. TOL. METRIC INCH SIPROMAC 600A & 620A USINAGE ± 0.1 ± 0.004" TOLERIE ± 0.5 ± 0.020" SOUDAGE ±...
Page 43
008-0402 UPPER SEAL BAR RUBBER 171-0180 TAPE CLEAR SUPER BOND 3/4" (0.024) 176-0200 TEFLON TAPE,PRESS.SENSITIVE 2" 683mm (0.08) -TWIN SEAL- MACHINE DEPT. TOL. METRIC INCH SIPROMAC 600A & 620A USINAGE ± 0.1 ± 0.004" TOLERIE ± 0.5 ± 0.020" SOUDAGE ±...
Page 49
31.5 VUE A REF. THIS SIDE OF SEAL BAR TO FIT FLUSH W/SUPPORT -OPTION 10mm- MACHINE DEPT. TOL. METRIC INCH SIPROMAC 600A & 620A USINAGE ± 0.1 ± 0.004" TOLERIE ± 0.5 ± 0.020" SOUDAGE ± 0. 5 ± 0.020"...
Page 50
PERMETTRE DE BOUGER LIBREMENT ALLOW TO MOVE FREELY INSTALLER CONTRE L'ENCOCHE DE L'ITEM #9 4 INSTALL AGAINST NOTCH OF ITEM #9 -OPTION 10mm- MACHINE DEPT. TOL. METRIC INCH SIPROMAC 600A & 620A USINAGE ± 0.1 ± 0.004" TOLERIE ± 0.5 ± 0.020" SOUDAGE ±...
Page 51
051-0740 WASHER 1/4" FLAT S/S COSSE DE CE CÔTÉ CONNECTOR ON THIS SIDE OPTION - TWIN SEAL / STAINLESS BAR MACHINE DEPT. TOL. METRIC INCH 600A & 620A SIPROMAC USINAGE ± 0.1 ± 0.004" TOLERIE ± 0.5 ± 0.020" SOUDAGE ± 0. 5 ±...
Page 52
13 OR 22° -OPTION - 255M³ PUMP SMALL HOLES MUST BE ON OIL RESERVOIR SIDE MACHINE DEPT. TOL. METRIC INCH 600A & 620A SIPROMAC USINAGE ± 0.1 ± 0.004" TOLERIE ± 0.5 ± 0.020" SOUDAGE ± 0. 5 ± 0.020"...
Page 53
13 OR 15° SMALL HOLES MUST BE ON OIL RESERVOIR SIDE -OPTION - 165M³ PUMP MACHINE DEPT. TOL. METRIC INCH 600A & 620A SIPROMAC USINAGE ± 0.1 ± 0.004" TOLERIE ± 0.5 ± 0.020" SOUDAGE ± 0. 5 ± 0.020"...
Page 54
004B1404 VACUUM / ATMOSPHERE VALVE ASSY. 10 OR 11 OR 15° -OPTION - 100M³ PUMP MACHINE DEPT. TOL. METRIC INCH 600A & 620A SIPROMAC USINAGE ± 0.1 ± 0.004" SMALL HOLE MUST BE TOLERIE ± 0.5 ± 0.020" 3 USE BLUE LOCTITE SOUDAGE ±...
Page 55
13 OR 22° -OPTION - 305M³ PUMP SMALL HOLES MUST BE ON OIL RESERVOIR SIDE MACHINE DEPT. TOL. METRIC INCH 600A & 620A SIPROMAC USINAGE ± 0.1 ± 0.004" TOLERIE ± 0.5 ± 0.020" SOUDAGE ± 0. 5 ± 0.020"...
Page 64
102-0330 ELBOW 1/4" NPT X 3/8" HOSE QUICK 100-0065 STREET ELBOW 1/4" NPT SS 102-0361 Y BRANCH 1/4'' MNPT X 3/8'' T. QUICK -OPTION - GAS MACHINE DEPT. TOL. METRIC INCH VACUUM SIPROMAC USINAGE ± 0.1 ± 0.004" TOLERIE ± 0.5 ± 0.020" SOUDAGE ± 0. 5 ±...
Page 65
106-00701 VALVE 3WAY 24V 1/4''NPT TO OTHER VALVE TO BELLOWS FROM PUMP -OPTION - AIR REGULATOR MACHINE DEPT. TOL. METRIC INCH VACUUM SIPROMAC USINAGE ± 0.1 ± 0.004" TOLERIE ± 0.5 ± 0.020" SOUDAGE ± 0. 5 ± 0.020" ST-GERMAIN DE GRANTHAM...
Page 66
102-0361 Y BRANCH 1/4'' MNPT X 3/8'' T. QUICK 001B6779 VALVE SUPPORT BRACKET 051-0144 SCREW #10-24 N.C 1/2"PAN PHIL. S/S 051-0572 NUT #10-24 NYLON LOCK S/S MACHINE DEPT. TOL. METRIC INCH VACUUM SIPROMAC USINAGE ± 0.1 ± 0.004" TOLERIE ± 0.5 ± 0.020" SOUDAGE ± 0. 5 ±...
Page 67
TO BELLOWS AIR PRESSURE INLET VACUUM FROM OTHER VALVE -OPTION - AIR REGULATOR MACHINE DEPT. TOL. METRIC INCH 600A & 620A SIPROMAC USINAGE ± 0.1 ± 0.004" TOLERIE ± 0.5 ± 0.020" SOUDAGE ± 0. 5 ± 0.020" ST-GERMAIN DE GRANTHAM...
Page 68
Section 8- Electrical drawing and part list ELECTRICAL DRAWINGS...
Page 69
14 (blk) 20 (blk) (20 yel) 20 (blk) (20 brn) (20 pur) (20 gry) category model volt. VACUUM PACK 1Ph 60Hz 620A SIPROMAC system circuit year month block St-Germain de Grantham QUEBEC ,CANADA usual 1 de fonctions concept draw 006-1420...
Page 70
( T / B OPTION ) W TB (20 yel) (20 brn) (20 pur) (20 gry) category model volt. VACUUM PACK 3Ph 60Hz 620A SIPROMAC month system circuit year block St-Germain de Grantham QUEBEC ,CANADA usual fonctions concept draw 006-1430...
Page 71
ORANGE Atmosphere JP3/1 BLUE JP3/1 PC BOARD category VACUUM PACK model volt. 620A SIPROMAC system circuit year month block St-Germain de Grantham RC filters must be connected on QUEBEC ,CANADA usual each AC coil (not shown on diagram) fonctions...
Page 72
WCV1 BLACK BLACK ooooooo GREEN SHIELD PC BOARD category VACUUM PACK model volt. 620A SIPROMAC system month circuit year block St-Germain de Grantham RC filters must be connected on QUEBEC ,CANADA usual each AC coil (not shown on diagram) fonctions...
Page 73
H:\DESSIN\DEPTDESS\PRODUCTS\VACUUMS\620A\ELECTRIQUE-PNEUMATIQUE\006-1437 620A CONT.VSD TRANSF.CONT.(yel 25) MC40 WCV2 ooooooo PC BOARD volt. category VACUUM PACK model 620A SIPROMAC system month circuit year block St-Germain de Grantham RC filters must be connected on QUEBEC ,CANADA usual each AC coil (not shown on diagram)
Need help?
Do you have a question about the SIPROVAC 620A and is the answer not in the manual?
Questions and answers