Heat Recovery Ventilator
PARTS IN THE BOX
Heat Recovery Ventilator, 1 pc
Hanging Chain Kit, 1 pc
Hardware Kit, 1 pc
Drain Hose Kit, 1 pc
Operation and Installation Manual, 1 pc
Your ventilation system should be installed in conformance with the appropriate provincial requirements or, in the absence of
such requirements, with the current edition of the National Building Code, and / or ASHRAE's "Good Engineering Practices".
United States
10048 Industrial Blvd., Lenexa, KS, 66215
Tel.: 800.747.1762 • Fax: 800.487.9915
Canada
50 Kanalflakt Way, Bouctouche, NB, E4S 3M5
Tel.: 800.565.3548 • Fax: 877.747.8116
Fantech reserves the right to modify, at any time and without notice, any or all of its products' features, designs,
components and specifications to maintain their technological leadership position.
Please visit our website www.fantech.net for more detailed technical information.
Installation and Operation Manual
Item #: 427354
Rev Date: 2020-02-18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the fantech VHR150 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SystemAir fantech VHR150

  • Page 1 Item #: 427354 Rev Date: 2020-02-18 Installation and Operation Manual VHR150 Heat Recovery Ventilator PARTS IN THE BOX Heat Recovery Ventilator, 1 pc Hanging Chain Kit, 1 pc Hardware Kit, 1 pc Drain Hose Kit, 1 pc Operation and Installation Manual, 1 pc Your ventilation system should be installed in conformance with the appropriate provincial requirements or, in the absence of such requirements, with the current edition of the National Building Code, and / or ASHRAE’s “Good Engineering Practices”.
  • Page 2 Note Warning/ Information Technical Practical tip Important information note PLEASE READ AND SAVE THESE INSTRUCTIONS Before installation careful consideration must be given to how this system will operate if connected to any other piece of mechanical equipment, i.e. a forced air furnace or air handler operating at a higher static pressure.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS DETERMINING YOUR AIRFLOW REQUIREMENT ........... . . 4 INSTALLATION EXAMPLES Fully dedicated system .
  • Page 4: Determining Your Airflow Requirement

    DETERMINING YOUR AIRFLOW REQUIREMENT Room Count Method Room classification Number of rooms CFM (L/s) CFM Required Master bedroom x 10 L/s (20 CFM) if yes add 10 L/s (20 CFM) Basement yes or no if no = 0 Bedrooms x 5 L/s (10 CFM) Living room x 5 L/s (10 CFM) Others...
  • Page 5: Installation Examples

    INSTALLATION EXAMPLES Suggested installation for: Example only – duct configuration may differ depending on the model. • Hydronic baseboard • Infloor heating FULLY DEDICATED SYSTEM • Electric baseboard BEST FOR NEW CONSTRUCTION • Mini split heat pump Benefits: Provides the best fresh air distribution in the Stale air is drawn from key areas of the home requiring local exhaust house;...
  • Page 6: Partially Dedicated System

    INSTALLATION EXAMPLES (CONT'D) Suggested installation for: • Central furnace (air DIRECT CONNECTION of the FRESH air to living area to the RETURN PLENUM handling unit or central of the AIR HANDLER (Stale air drawn from key areas of home) air conditioners) •...
  • Page 7: Simplified Installation

    INSTALLATION EXAMPLES (CONT'D) Suggested installation for: DIRECT CONNECTION of both the HRV SUPPLY AIR STREAM and EXHAUST AIR STREAM • When bathroom and kitchen to the FURNACE COLD AIR RETURN already have local exhaust SIMPLIFIED INSTALLATION (GOOD) system (RETURN/RETURN METHOD) - OPTION 1 •...
  • Page 8: Option 1

    Installation examples (Cont'd) Suggested installation for: DIRECT CONNECTION of the HRV SUPPLY AIR STREAM to the SUPPLY AIR SIDE on the • When bathroom and FURNACE & EXHAUST AIR STREAM to the FURNACE COLD AIR RETURN kitchen already have local exhaust system SIMPLIFIED INSTALLATION (GOOD) •...
  • Page 9: Exterior Ducting Installation

    EXTERIOR DUCTING INSTALLATION WEATHERHOOD LOCATION OUTSIDE CORNER INSIDE CORNER • Decide where your intake and exhaust hoods will be located. 36" (1m) 36” (1m) min. min. Locating the Intake Weatherhood • Should be located upstream (if there are prevailing winds) from the 6' (2m) exhaust outlet.
  • Page 10: Interior Ducting Installation

    INTERIOR DUCTING INSTALLATION • To maximize airflow through the ductwork system, all ducts should be kept short and have as few bends or elbows as possible. • 45º elbows are preferable to 90º. • Use “Y“ ducts instead of “T” ducts whenever possible. •...
  • Page 11: Hrv Installation

    HRV INSTALLATION LOCATION The HRV must be located in a conditioned space where it will be possible to conveniently service the unit. Typically the HRV would be located in the mechanical room or an area close to the outside wall where the weatherhoods will be mounted.
  • Page 12 INSTALLING DRAIN LINE Through normal operation and during its defrost mode, the HRV may produce some condensation. This water should flow into a nearby drain, or be taken away by a condensate pump. The HRV and all condensate lines must be installed in a space where the temperature is maintained above the freezing point. A “P”...
  • Page 13: Airflow Adjustment & Balancing

    AIRFLOW ADJUSTMENT & BALANCING BALANCING THE AIRFLOWS IS CRUCIAL TO ENSURE OPTIMAL OPERATION OF THE UNIT. IF THE AIRFLOW IS NOT PROPERLY BALANCED, THE FOLLOWING ISSUES MAY OCCUR: • SIGNIFICANT POSITIVE OR NEGATIVE PRESSURE INSIDE THE HOUSE • UNIT’S EFFICIENCY MAY BE NEGATIVELY AFFECTED •...
  • Page 14: Balancing Steps

    BALANCING STEPS Use balancing chart located on the BALANCING CHART (example only) door of the HRV Airflow Normal Speed Reduced Speed ∆In W.G. ∆In W.G. STEP #1: Identify the desired airflow using the provided chart. From ∆Pa ∆Pa Pressure reading Pressure reading the desired airflow (left column) identify the pressure reading 0.36...
  • Page 15: Low Voltage Control Systems

    Low Voltage Control Systems * Please see instruction manuals for individual controls for proper wiring and set up of control systems. CENTRAL CONTROLS These cannot be used with another central control Ensure that unit is not CONTROLS FEATURES CONNECT TO plugged when connecting ECO-Touch®...
  • Page 16: Wiring Diagram

    WIRING DIAGRAM HIGH fantech...
  • Page 17 WIRING DIAGRAM (CONT'D) WIRING DIAGRAM TO Standard Accessory Control Contact Standard Furnace Interlock Wiring FURNACE THERMOSTAT TERMINALS FOUR WIRE TWO WIRE heating only FOR A FURNACE CONNECTION TO A COOLING SYSTEM: On some newer furnaces and older FURNACE thermostats, energizing the R and 24-VOLT TERMINAL BLOCK G terminal at the furnace has the...
  • Page 18: Troubleshooting

    TROUBLESHOOTING Problem Causes Solutions Air is too dry Dehumidistat control is set too low Increase the desired level of humidity. Change ventilation mode from continuous mode to standby. HRV out of balance Have contractor balance HRV airflows Air is too humid Dehumidistat control is set too high Reduce the desired level of humidity.
  • Page 19: Hrv Maintenance Chart

    HRV MAINTENANCE CHART The Best Limited Warranty in the Business Maintenance Required Recommended Frequency Date Maintenance Performed • The heat recovery aluminum core Check and Clean Filters Every 3 months or if has a limited lifetime warranty. dirty • The motors found in all Fantech Check Heat Recovery Every 6 months HRV’s require no lubrication, and...
  • Page 20 NOTES fantech...
  • Page 21 No. d'article #: 427354 Date de révision: 2020-02-18 Installation and Operation Manual VHR150 Ventilateur récupérateur de chaleur PIÈCES DANS LA BOÎTE Ventilateur récupérateur de chaleur, 1 pc Kit de suspension, 1 pc Vis et matériel d'assemblage, 1 pc Tuyau d’évacuation , 1 pc Manuel d'installation, 1 pc Votre système de ventilation doit être installé...
  • Page 22 Note Avertissement/ Information Information Conseil Note importante technique pratique VEUILLEZ LIRE ET CONSERVER CES INSTRUCTIONS Avant de procéder à l’installation, examinez avec soin la façon dont le système fonctionnera s’il est relié à tout autre appareil mécanique, notamment une fournaise à air pulsé ou un appareil de traitement d’air dont la pression statique est plus élevée.
  • Page 23 TABLE DES MATIÈRES DÉTERMINER VOS BESOINS DE VENTILATION ........... . . 24 EXEMPLES D'INSTALLATION Système entièrement spécialisé...
  • Page 24: Déterminer Vos Besoins De Ventilation

    DÉTERMINER VOS BESOINS DE VENTILATION Méthode compte de pièces Pi 3 /min (L/s) Liste des pièces Nombre de pièces PCM Required x 10 L/s (20 pi 3 /min) Chambre principale 3 /min Si oui, ajoutez 10 L/s (20 pi Sous-sol oui ou no Sinon = 0 x 5 L/s (10 pi 3 /min)
  • Page 25: Exemples D'installation

    EXEMPLES D'INSTALLATION Installation suggérée pour: • Plinthe à eau chaude Exemple seulement – la configuration des conduits peut être différente selon le modèle. • Plancher chauffant • Plinthe électriques SYSTÈME ENTIÈREMENT SPÉCIALISÉ • Thermopompe mural bibloc (NOUVELLE CONSTRUCTION) Avantages: Fourni la meilleure répartition de l’air frais dans la maison;...
  • Page 26: Système Partiellement Spécialisé

    EXEMPLES D'INSTALLATION (SUITE) Installation suggérée pour: RACCORDEMENT DIRECT du FLUX D’AIR D’APPROVISIONNEMENT à la BOUCHE DE REPRISE • Fournaise centrale (unité D’AIR DE LA FOURNAISE de traitement d’air, air (L’air vicié est aspiré à partir des endroits clés de la maison.) climatisé...
  • Page 27: Installation Simplifiée

    EXEMPLES D'INSTALLATION (SUITE) Installation suggérée pour: RACCORDEMENT DIRECT du FLUX D’AIR D’APPROVISIONNEMENT et du FLUX D’AIR ÉVACUÉ • Lorsque la salle de bain DU VRC à la BOUCHE D’AIR DE LA FOURNAISE et la cuisine ont déjà un système d’échappement INSTALLATION SIMPLIFIÉE (BONNE) •...
  • Page 28: Option 2

    Exemple d'installation (suite) Installation suggérée pour: RACCORDEMENT DIRECT du FLUX D’AIR D’APPROVISIONNEMENT du VRC à la BOUCHE DE • Lorsque la salle de bain REPRISE D’AIR DE LA FOURNAISE et la cuisine ont déjà un système d’échappement INSTALLATION SIMPLIFIÉE (BONNE) •...
  • Page 29: Installation Des Conduits Extérieurs

    INSTALLATION DES CONDUITS EXTÉRIEURS EMPLACEMENT DES HOTTES Coin extéreur Coin intérieur OUTSIDE CORNER INSIDE CORNER • Décidez de l’emplacement des hottes d’aspiration et d’évacuation. 36po (1m) 36po (1m) 36" (1m) 36” (1m) min. min. Emplacement de la hotte d’aspiration • Doit être située en amont de la sortie d’évacuation (en présence de vents 3pi (900 mm) dominants).
  • Page 30: Installation Des Conduits Intérieurs

    INSTALLATION DES CONDUITS INTÉRIEURS • Pour maximiser le débit d’air dans le réseau de conduits, assurez-vous que tous les conduits sont le plus court et le plus droit possible. • Il est préférable d’utiliser des coudes de 45 degrés plutôt que des coudes de 90 degrés.
  • Page 31: Installation Du Vrc

    INSTALLATION EMPLACEMENT Le VRC doit être situé dans un endroit chauffé où il sera possible d’en effectuer l'entretient convenablement. Généralement, le VRC doit être situé dans la chambre des appareils mécaniques ou à proximité. S’il n’y a pas de sous-sol ou si le sous-sol ne convient pas, il est possible d’installer l’appareil dans la lingerie ou dans la buanderie. Installation dans un grenier doit remplir les conditions suivantes: •...
  • Page 32 INSTALLATION DU TUYAU D'ÉCOULEMENT En mode normal ainsi qu’au cours du cycle de dégivrage, le VRC peut produire de la condensation. L’eau de condensation doit d’écouler vers le drain avoisinant ou être aspirée par une pompe à condensat. Le VRC et toutes les canalisations de condensats doivent être installés dans un endroit où la température ambiante est maintenue au-dessus du point de congélation.
  • Page 33: Équilibrage Du Débit D'air

    ÉQUILIBRAGE DU DÉBIT D’AIR SI LES FLUX D’AIR DE L’APPAREIL NE SONT PAS CORRECTEMENT ÉQUILIBRÉS… • L’EFFICACITÉ DE L’APPAREIL PEUT ÊTRE RÉDUITE. • DES DOMMAGES AU NOYAU DE RÉTABLISSEMENT DE LA CHALEUR PEUVENT SURVENIR. • UN REFOULEMENT DE L’AIR DANS VOS APPAREILS DE CHAUFFAGE À COMBUSTION •...
  • Page 34: Étapes De Balancement

    ÉTAPES DE BALANCEMENT Utilisez la charte de balancement CHARTE DE BALANCEMENT (exemple seulement) localisée sur la porte du VHC Débit d'air Vitesse normale Vitesse réduite Étape 1: Identifiez le débit d’air désiré en vous référent à la charte ∆In W.G. ∆In W.G.
  • Page 35: Systèmes De Contrôle À Basse Tension

    SYSTÈME DE CONTRÔLE À BASSE TENSION * Veuillez voir les instructions individuelles des contrôles pour le câblage et la mise en pièce appropriée. CONTRÔLES CENTRALS Ceux-ci ne peuvent pas être utilisés avec une autre commande centrale Assurez-vous que CONTRÔLE CARACTÉRISTIQUES CONNEXION À...
  • Page 36 SCHÉMAS ÉLECTRONIQUES HIGH fantech...
  • Page 37 SCHÉMAS ÉLECTRONIQUES (SUITE) CONNEXION ÉLECTRIQUE Câblage standard de synchronisation avec une fournaise Standard Furnace Interlock Wiring À UNE FOURNAISE BORNES DU THERMOSTAT TERMINALS TERMINALS FOUR QUATRE FILS WIRE DEUX FILS TWO WIRE chauffage seulement heating only DANS LE CAS D'UNE FOURNAISE RACCORDÉE À...
  • Page 38: Shémas Électriques

    DÉPANNAGE Problème Causes Solutions L’air est trop sec – Le déshumidistat est réglé trop bas – Augmentez le niveau voulu d’humidité. Faites passer le mode de ventilation de « continu » à « attente ». – Le VRC est déséquilibré –...
  • Page 39: Tableau D'entretien Du Vrc

    TABLEAU D'ENTRETIEN DU VRC La meilleure garantie limitée sur le marché • La meilleure garantie limitée sur le Entretien requis Fréquence recommandée Date de l'entretien marché. Vérifiez et nettoyez les à chaque 3 mois, ou s'ils • Le noyau récupérateur de chaleur filtres sont sales en aluminium bénéfice d'une...
  • Page 40: Parts List

    Parts list • Liste des composantes VHR150 BOM # Description (99203) * If the first set of digits (can be between 7 and 10 R2E 190 Radical, Rep. Kit 405520 digits long) of your serial number is # 1004982580 or lower, your replacement door kit is #422806.
  • Page 41 Notes fantech...
  • Page 42 Notes fantech...
  • Page 43 Notes fantech...
  • Page 44 Fantech reserves the right to make technical changes. Fantech se réserve le droit de faire des changements tech- For updated documentation please refer to www.fantech.net niques. Pour de la documentation à jour, s'il vous plaît se référer au www.fantech.net Fantech®...

This manual is also suitable for:

99203

Table of Contents