38XR Digital Multimeter Contents Safety Information ..................2 Symbols Used in this Manual ............... 2 Introduction....................3 Making Measurements..................3 Verify Instrument Operation ................. 3 Range Selection................... 3 or - Correcting an Overload ( ) Indication .......... 3 Measuring DC Voltage ..........See Figure -1-..4 Measuring AC + DC Voltage (True rms) ....
Safety Information • The 38XR Digital Multimeter is UL, CSA, and EN61010-1 certified for Installation Category III – 1000V and Category IV – 600V. It is recommended for use with fixed equipment installations, such as, distribution panels, feeders and short branch circuits and lighting systems in large buildings; and for the primary supply level, such as, an electric meter or an overhead or underground utility service.
Introduction The 38XR is a true rms autoranging handheld digital multimeter for measuring or testing the following: • DC and AC Voltage • Capacitance • DC and AC Current • Diodes • Resistance • Continuity • Frequency • dBm • Dutycycle •...
Measuring DC Voltage See Figure 1. Set the Function Switch to 2. If RANGE is displayed, press the RANGE button to enable autoranging. 3. Connect the Test Leads: Red to , Black to COM 4. Connect the Test Probes to the circuit test points. 5.
Measuring DC Current See Figure 1. Set the Function Switch to a current function, µA, mA, or 10A. 2. If AC or AC+DC is displayed, press the yellow button to turn on DC. 3. If the µA function is selected and RANGE is displayed, press the RANGE button to enable autoranging.
Testing for Continuity See Figure 1. Set the Function Switch to Ω 2. If is displayed, press the yellow button to display 3. Connect the Test Leads: Red to , Black to COM 4. Turn off power to the circuit being measured. 5.
Measuring Frequency See Figure -11- 1. Set the Function Switch to Hz. 2. If % is displayed, press the yellow button to display Hz. 3. If RANGE is displayed, press the RANGE button to enable autoranging. 4. Connect the Test Leads: Red to Hz, Black to COM 5.
True-rms Measurements For ac measurements most DMMs average the ac input signal and display the result as an estimated rms value. This average-responding method is accurate for sinusoidal waveforms, but can be very inaccurate for distorted waveforms. To ensure the most accurate measurements, always use a true-rms DMM when measuring ac voltage or ac current on circuits for the following kinds of applications: •...
Beeper Off The beeper is an aural indicator to identify when the DMM is performing a function, making a range change, detecting a limit, and so on. To disable the beeper use the following procedure: 1. Set the Function Switch to OFF. 2.
Fuse: Fast Blow .5A/1000V, minimum interrupt rating 30 kA (6.3 x 32 mm) (Meterman FP500) To replace the 10 A fuse: 1) Remove the battery. 2) Remove the four rear-case screws.
Page 13
“Where to Buy” section on www.metermantesttools.com for a list of distributors near you. Additionally, in the United States and Canada In-Warranty repair and replacement units can also be sent to a Meterman Test Tools Service Center (see below for address). Non-Warranty Repairs and Replacement – US and Canada Non-warranty repairs in the United States and Canada should be sent to a Meterman Test Tools Service Center.
(1) year period. Meterman Test Tools shall not be liable for loss of use of the multimeter or other incidental or consequential damages, expenses, or economical loss or for any claim or claims for such damage, expenses or economical loss.
Page 15
Crest Factor: ≤ 3 Safety: Input impedance: 10 M Conforms to EN61010-1, Rev-2 CAT III AC coupled true rms specified from 5 % 1000V, CAT IV 600V, class 2, pollution to 100 % of range overload protection: degree II; CSA 22.2 -1010-1. 1000 V dc or 750 V ac rms P $ ! In accordance with...
Page 17
REL: Initiates relative measurements. Ranges: -13 dBm to +50 dBm PEAK+/-: Record the peak+ or peak- value Resolution: 0.01 dBm in a measurement. Accuracy: RANGE: Initiates manual range mode. ±0.7 dB + 8 dgts ( 45 Hz to 5 kHz ) Backlight: Backlight auto-off approx.