Page 1
38XR Professional Digital Multimeter True-RMS with Optical PC Interface Users Manual • Mode d'emploi • Bedienungshandbuch • Manuale d'Uso • Manual de uso...
Page 2
RS232 MADE IN TAIWAN PATENTS PENDING metermantesttools.com...
38XR Digital Multimeter Contents Safety Information ..................2 Symbols Used in this Manual ............... 2 Introduction....................3 Making Measurements..................3 Verify Instrument Operation ................. 3 Range Selection................... 3 or - Correcting an Overload ( ) Indication .......... 3 Measuring DC Voltage ..........See Figure -1-..4 Measuring AC + DC Voltage (True rms) ....
Safety Information • The 38XR Digital Multimeter is UL, CSA, and EN61010-1 certified for Installation Category III – 1000V and Category IV – 600V. It is recommended for use with fixed equipment installations, such as, distribution panels, feeders and short branch circuits and lighting systems in large buildings; and for the primary supply level, such as, an electric meter or an overhead or underground utility service.
Range Selection In addition to autoranging the 38XR allows you to manually select and lock a range by pressing the RANGE button. RANGE appears on the display to indicate that manual ranging is active and the range is locked. When appropriate, each subsequent press of the range button steps the meter to the next higher range.
Measuring DC Voltage See Figure 1. Set the Function Switch to 2. If RANGE is displayed, press the RANGE button to enable autoranging. 3. Connect the Test Leads: Red to , Black to COM 4. Connect the Test Probes to the circuit test points. 5.
Measuring DC Current See Figure 1. Set the Function Switch to a current function, µA, mA, or 10A. 2. If AC or AC+DC is displayed, press the yellow button to turn on DC. 3. If the µA function is selected and RANGE is displayed, press the RANGE button to enable autoranging.
Match the polarity of the adapter to the polarity of the thermocouple. 3. Connect the TEMP adapter to the and COM inputs. Note: The 38XR is compatible with all K-type thermocouples. The K-type bead thermocouple supplied with the meter is not intended for contact with liquids or electrical circuits.
Measuring dBm See Figure -13- The 38XR measures dBm relative to 1 mW referenced to 50 Ω. That is, 10 dBm = 10 mW, 0 dBm = 1 mW, -10 dBm = 0.1 mW, etc. 1. Set the Function Switch to 2.
• Pulsed Signals • Any non-sinusoidal ac waveform The 38XR displays the dc, ac, or ac+dc components of a voltage or current measurment. The dc component is the shift level or baseline. The ac component is the area under the waveshape. The ac+dc component is the combined effect of the ac and dc components.
Beeper Off The beeper is an aural indicator to identify when the DMM is performing a function, making a range change, detecting a limit, and so on. To disable the beeper use the following procedure: 1. Set the Function Switch to OFF. 2.
See Figure -14- The 38XR includes an RS232 IR communication port for downloading measurement data (value, function, and range) to a PC. The 38SW Accessory Kit (software and cable) povides a graphical user interface for the PC to collect, store, and display measurement data.
Page 13
“Where to Buy” section on www.metermantesttools.com for a list of distributors near you. Additionally, in the United States and Canada In-Warranty repair and replacement units can also be sent to a Meterman Test Tools Service Center (see below for address). Non-Warranty Repairs and Replacement – US and Canada Non-warranty repairs in the United States and Canada should be sent to a Meterman Test Tools Service Center.
(1) year period. Meterman Test Tools shall not be liable for loss of use of the multimeter or other incidental or consequential damages, expenses, or economical loss or for any claim or claims for such damage, expenses or economical loss.
Crest Factor: ≤ 3 Safety: Input impedance: 10 M Conforms to EN61010-1, Rev-2 CAT III AC coupled true rms specified from 5 % 1000V, CAT IV 600V, class 2, pollution to 100 % of range overload protection: degree II; CSA 22.2 -1010-1. 1000 V dc or 750 V ac rms P $ ! In accordance with...
Page 17
REL: Initiates relative measurements. Ranges: -13 dBm to +50 dBm PEAK+/-: Record the peak+ or peak- value Resolution: 0.01 dBm in a measurement. Accuracy: RANGE: Initiates manual range mode. ±0.7 dB + 8 dgts ( 45 Hz to 5 kHz ) Backlight: Backlight auto-off approx.
Page 26
400 Britannia Rd. E. Unit #1 Mississauga, ON L4Z 1X9 Tel: 905-890-7600 Fax: 905-89-6866 European Correspondence Address* Meterman Test Tools Europe P.O. Box 1186 5602 BD Eindhoven The Netherlands *Correspondence only - no repair or replacement available from this address. European customers please contact your distributor.
Need help?
Do you have a question about the 38XR and is the answer not in the manual?
Questions and answers