  • Page 1 33XR Professional Digital Multimeter with Temperature and Capacitance Users Manual • Mode d'emploi • Bedienungshandbuch • Manuale d'Uso • Manual de uso...
  • Page 2 MADE IN TAIWAN PATENTS PENDING metermantesttools.com...
  • Page 3: Table Of Contents

    33XR Digital Multimeter Contents Safety Information ................2 Introduction....................3 Making Measurements................. 3 Verify Instrument Operation ..............3 Correcting an Overload ( ) Indication ........... 3 Measuring DC Voltage........See Figure -1-....3 Measuring AC Voltage........See Figure -2-....3 Preparing for Current Measurements............3 Measuring DC Current........See Figure -3-....
  • Page 4: Safety Information

    Safety Information To avoid electric shock, personal injury, damage to the meter or the equipment under test, adhere to the following practices: • The 33XR Digital Multimeter is UL, cUL, and EN61010-1 certified for Installation Category III – 600V and Category II – 1000V. It is recommended for use with local level power distribution, appliances, portable equipment, etc, where only smaller transient overvoltages may occur, and not for primary supply lines, overhead lines and cable systems.
  • Page 5: Introduction

    Introduction The 33XR is a manual ranging handheld digital multimeter for measuring or testing the following: • DC and AC voltage • Temperature • DC and AC current • Capacitance • Resistance • Diodes • Frequency • Continuity Additional features include the following modes: MIN MAX, HOLD, REL (relative), and Peak±...
  • Page 6: Measuring Dc Current

    Measuring DC Current See Figure 1. Set the Range Switch to an appropriate range. Select the highest range and work down if the current level is unknown. 2. Connect the Test Leads: Red to mA or 10A, Black to COM 3.
  • Page 7: Measuring Capacitance

    Measuring Capacitance See Figure 1. Set the Range Switch to P . 2. Connect the Test Leads: Red to COM, Black to mA 3. Turn off power to the circuit being measured. 4. Discharge the capacitor using a 100 kΩ resistor. 5.
  • Page 8: Peak Hold Measurements

    Peak Hold Measurements Note: The PEAK function must be calibrated to meet the specifications. Peak Hold records and stores the positive and negative peak values that occur while measuring an ac signal. To calibrate the Peak Hold function press the PEAK button for more than 2 seconds.
  • Page 9: Product Maintenance

    Fuse: Fast Blow .315A/1000V minimum interrupt rating 30 kA (6.3 x 32 mm) (Meterman FP300) To replace the 10 A fuse: 1) Remove the battery. 2) Remove the four rear-case screws.
  • Page 10: Warranty

    (1) years period. Meterman Test Tools shall not be liable for loss of use of the multimeter or other incidental or consequential damages, expenses, or economical loss or for any claim or claims for such damage, expenses or economical loss.
  • Page 11: Specifications

    Specifications Approvals: General Specifications LISTED Display: 3 ¾ digit liquid crystal display 950Z (LCD)(3999 count) with a 41-segment analog bar-graph. Safety: Conforms to UL1244; EN61010- 1: Polarity: Automatic, positive implied, Cat II – 1000V / Cat III - 600V; Class 2, negative polarity indication.
  • Page 12 AC VOLTS (45 Hz - 500 Hz) RESISTANCE Ranges: 400mV, 4V, 40V, 400V, 750V ac Ranges: 400Ω, 40kΩ, 4MΩ Resolution: 100 µV Resolution: 100 mΩ Accuracy: Accuracy: ±(1.0 % of reading + 4 digits) on ±(1.5 % of reading + 4 digits) 400Ω, 40kΩ...
  • Page 13 CONTINUITY PEAK+/-: Displays the peak+ or peak- value Audible indication: Less than 35 Ω in an AC voltage or AC current measurement. Response time: 100 ms Response time: more than 1 ms Overload protection: 1000 V dc or 750 V ac HOLD: Holds the latest reading on the display.