Circuit Diagrams - Gastro-Cool GCDC280 Instructions For Use Manual

Display cooler back bar cooler
Hide thumbs Also See for GCDC280:
Table of Contents

Advertisement

Available languages

Available languages

Undercounter cooler
Model no
GcUc100
Climate classification
0, 1, 2, 3, 4, 6 / N
Foam Agent
Cyclopentane
Volume
138 L
Protection class
1
Voltage
230 V
Frequency
50 Hz
Rated current
1.25 A
Power
200 W
Lamp Power
10 W
Energy consumption
~2.2 kWh / 24 h
Refrigerant
R600a (35 g)
Dimensions h × W × D
90 × 60 × 52 cm
net weight
48 kg
Glas Door cooler
Model no
GcGD360
Climate classification
0, 1, 2, 3, 4, 6 / N
Foam Agent
Cyclopentane
Volume
360 L
Protection class
1
Voltage
230 V
Frequency
50 Hz
Rated current
1,3 A
Power
180 W
Lamp Power
10 W
Energy consumption
~
1.9 kWh / 24 h
Refrigerant
R600a (80 g)
Dimensions h × W × D
174 × 62 × 63.5 cm
net weight
kg
69
48
GcUc200
GcUc300
0, 1, 2, 3, 4, 6 / N
0, 1, 2, 3, 4, 6 / N
Cyclopentane
Cyclopentane
208 L
330 L
1
1
230 V
230 V
50 Hz
50 Hz
1.66 A
1.66 A
230 W
350 W
10 W
10 W
~2.6 kWh / 24 h
~3.8 kWh / 24 h
R600a (64 g)
R600a (85 g)
90 × 90 × 52 cm
90 × 135 × 52 cm
62 kg
80 kg
All appliance-specific data have been determined by the appliance
manufacturer by means of Europe-wide standardised measuring
methods under laboratory conditions. These are specified in EN62552.
The actual energy consumption of the appliances during use is of
course dependent upon the installation site and user behaviour, and
so may also be higher than the values determined by the appliance
manufacturer under standard conditions.
The expert is familiar with this context and carries out the tests with
special measuring instruments according to the applicable standards.