General Information

This Gas Barbecue is certified under Canadian and American National Standards, CSA 1.6-2015 and ANSI
Z21.58-2015 respectively for Outdoor Gas Grills and should be installed to conform according to local
codes. In absence of local codes, install to the current CAN B149.1 Natural Gas and Propane Installation
Code in Canada or to the National Fuel Gas Code, ANSI Z223.1 in the United States.
If a rotisserie motor is used, it must be electrically grounded in accordance with local codes or, in
absence of local codes, with the current CSA C22.1 Canadian Electrical Code in Canada or the National
Electrical Code, ANSI/NFPA 70 in the United States.
!
Propane Cylinder Specifications
!
If the gas grill is being supplied with propane from a portable cylinder, a regulator specified by the
manufacturer must be used. The regulator must supply a pressure of 11 inches water column (0.39 PSI)
to the gas grill and have a QCC1 type fitting. Cylinders to be used with this unit must be supplied with
a QCC1 cylinder valve. A QCC1 cylinder has a positive seating connection, which will not allow gas flow
until a positive seal has been achieved. It is also equipped with an excess flow device. In order to attain
full flow to the grill, the valves must be in the off position when the cylinder valve is turned on.
A dented or rusty cylinder may be hazardous and should be checked by your propane supplier. Never
use a cylinder with a damaged valve. Use only a propane supply cylinder constructed and marked
in accordance with the specifications for LP-gas cylinders of the National Standard of Canada, CAN/
CSA-b339, Cylinders, Spheres and Tubes for Transportation of Dangerous Goods; and Commission, as
applicable or the Specifications for LP-Gas Cylinders of the U.S. Department of Transportation (D.O.T.).
Cart models have been designed for use with a 20 lb (9.1 kg) size propane cylinder only (not supplied).
The propane cylinder must be provided with a cylinder connection device compatible with the
connection for outdoor cooking appliances. The propane cylinder must be provided with a shut-
off valve terminating in a propane cylinder valve type QCC1, and a safety relief device having direct
communication with the vapor space of the cylinder. The cylinder supply system must be arranged for
vapor withdrawal and the cylinder shall include a collar to protect the cylinder valve. The cylinder shall
incorporate a listed OPD (overfill protection device). Do not store a spare LP-gas cylinder under or near
this appliance. Never fill the cylinder beyond 80 percent full. If the preceding information is not followed
exactly, a fire causing death or serious injury may occur.

Gas Hook-Up Instructions

!
Propane Cylinder Installation: Set cylinder into hole in bottom shelf. Other cylinders may be acceptable
provided they fit properly into the tank retaining ring.
N415-0518 JAN 02.19
N415-0518 JAN 02.19.indd 5
WARNING!
This product can expose you to chemicals including lead and lead compounds, which
are known to the State of California to cause cancer, and chemicals including di-n-butyl phthalate,
which are known to the State of California to cause birth defects or other reproductive harm. For
more information go to www.P65Warnings.ca.gov.
WARNING!
If these instructions are not followed exactly, a fire causing death or serious injury
may occur.
WARNING!
Do not store a spare propane cylinder on the shelf beneath the barbecue.
WARNING!
A fire will result if the gas supply hose makes contact with the underside of the grill or drip
pan.