Figure 4: The curves above show the effect of the 'Treble Tilt', 'Bass Tilt'
and 'Bass Roll-Off ' controls on the free field response.
SYSTEM SPECIFICATIONS
Lower cut-off frequency, –3 dB:
Upper cut-off frequency, –3 dB:
Free field frequency response of system:
58 Hz – 20 kHz (± 2.0 dB)
Maximum short term sine wave acoustic output on axis
in half space, averaged from 100 Hz to 3 kHz:
@ 1 m
@ 0.5 m
Maximum long term RMS acoustic output in same
conditions with IEC weighted noise (limited by driver
unit protection circuit):
@ 1 m
Maximum peak acoustic output per pair on top of
console, @ 1 m from the engineer with music material:
> 108 dB
Self generated noise level in free field @ 1 m on axis:
< 10 dB (A-weighted)
Harmonic distortion at 85 dB SPL @ 1 m on axis:
Freq:
50...100 Hz
> 100 Hz
Drivers:
Bass
130 mm (5") cone
Treble
19 mm (
3
/
") metal dome
4
Both drivers are
magnetically shielded
Weight:
5.6 kg (12.3 lb)
Dimensions:
Height
299 mm
(including Iso-Pod™ table stand)
Height
285 mm
(without Iso-Pod™ table stand)
Width
189 mm
Depth
178 mm
Genelec Document D0058R001 Copyright Genelec Oy 12.2004. All data subject to change without prior notice
CROSSOVER SECTION
< 55 Hz
Analog connectors:
Input connector: XLR female,
> 21 kHz
(DIGITAL IN AES/EBU, ANALOG IN)
balanced 10 kOhm,
pin 1 gnd, pin 2 +, pin 3 -
Analog output: XLR male, (ANALOG OUT)
balanced 100 Ohm
pin 1 gnd, pin 2 +, pin 3 -
> 100 dB SPL
> 106 dB SPL
Input level for 100 dB SPL output at 1 m:
-6 dBu at volume control max
Volume control range:
> 97 dB SPL
-80 dB relative to max output
Output signal level is 0 dB relative to input signal level
but adjustable by volume control
Crossover frequency, Bass/Treble:
Treble Tilt control operating range:
0 to –2 dB @ 15 kHz
< 2 %
Bass Roll-Off control operating in a –6 dB step @ 85 Hz
< 0.5 %
(to be used in conjunction with a 7050A subwoofer)
Bass Tilt control operating range in –2 dB steps:
0 to –6 dB @ 100 Hz
The 'CAL' position is with all tone controls set to 'off ' and
the input sensitivity control to maximum (fully
clockwise).
(11
13
/
")
16
(11
1
/
")
4
(7
7
/
")
16
(7")
International enquiries:
Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland
Phone +358 17 83881
Fax +358 17 812 267
Email genelec@genelec.com
Figure 5: The curve group shows the horizontal directivity characteristics
of the 8130A in its vertical configuration measured at 1m. The lower
curve shows the system's power response.
DIGITAL SECTION
Input connector (DIGITAL IN AES/EBU, ANALOG IN)
DIGITAL THRU connector
Word length:
Input format:
Input termination impedance:
Input sampling rate:
Dynamic range:
AMPLIFIER SECTION
3.0 kHz
Bass amplifier output power with an 8 Ohm load:
Treble amplifier output power with an 8 Ohm load: 40 W
Long term output power is limited by driver unit
protection circuitry.
Amplifier system distortion at nominal output:
Signal to Noise ratio, referred to full output:
Mains voltage:
Voltage operating range:
Power consumption:
In the U.S. please contact:
In China please contact:
Genelec, Inc., 7 Tech Circle
Genelec China Representative Office
Natick, MA 01760, USA
Soho New Town, 88 Jianguo Road
Phone +1 508 652 0900
D-1504, Chaoyang District
Fax +1 508 652 0909
Beijing 100022, China
Email genelec.usa@genelec.com
Phone +86 10 8580 2180 Fax +86 10 8580 2181
Email genelec.china@genelec.com
XLR female
XLR male
16...24 bits
AES/EBU
110 Ohm
29-200 kHz (no de-emphasis)
>113 dB (A weighted,
triangular PDF dither, 24 bit
data)
40 W
THD
< 0.05 %
SMPTE-IM
< 0.05 %
CCIF-IM
< 0.05 %
DIM 100
< 0.05 %
Bass
> 100 dB
Treble
> 100 dB
100, 120, 220 or 230 V
according to region
±10 %
Idle
15 VA
Full output
80 VA