Download Print this page

Genelec 8050A Datasheet page 4

Active monitoring system
Hide thumbs Also See for 8050A:

Advertisement

8050A Data Sheet
Figure 3: The upper curve group shows the horizontal directivity char-
acteristics of the 8050A measured at 1 m. The lower curve shows the
systems power response.
SyStem SpeciFicAtionS
Lower cut-off frequency, -3 dB
Upper cut-off frequency, -3 dB
Free field frequency response of system (± 2.0 dB)
Maximum short term sine wave acoustic output on axis in half
space, averaged from 100 Hz to 3 kHz
@ 1 m
@ 0.5 m
Maximum long term RMS acoustic output in same conditions
with IEC weighted noise (limited by driver unit protection circuit)
@ 1 m
Maximum peak acoustic output per pair above console top,
@ 1 m from the engineer with music material
Self generated noise level in free field @ 1m on axis
(A-weighted)
Harmonic distortion at 90 dB SPL @ 1m on axis
Freq. 50 to 100 Hz
> 100 Hz
Drivers:
Bass
Treble
Both drivers are magnetically shielded
Weight:
Dimensions:
Height (without Iso-Pod™ table support
Height (including Iso-Pod™ table support)
Width
Depth
Genelec Document BBA0004001a Copyright Genelec Oy 4.2007. All data subject to change without prior notice
Figure 4: The curves above show the effect of the "bass tilt", "treble
tilt", "desktop low frequency" and "bass roll-off" controls on the free field
response.
AmpliFier Section
8050A
Bass amplifier short term output power
≤ 35 Hz
Treble amplifier shortterm output power
≥ 20 kHz
Long term output power is limited by driver unit protection
circuitry
38 Hz - 20 kHz
Amplifier system distortion at nominal output
≥ 110 dB SPL
≥ 116 dB SPL
≥ 101 dB SPL
Signal to Noise ratio, referred to full output
≥ 115 dB SPL
Mains voltage
≤ -10 dB
Voltage operating range
Power consumption
< 2 %
< 0.5 %
205 mm (8") cone
25 mm (1") metal dome
croSSover Section
12.7 kg (28 lbs)
Input connector XLR female
Input impedance
433 mm (17 1/16")
Input level for maximum short term output of 100 dB SPL @ 1m
452 mm (17 13/16")
286 mm (11 1/4")
Crossover frequency, Bass/Treble
278 mm (10 15/16")
Treble tilt control operating range in 2 dB steps
Desktop low frequency control operating range
Bass roll-off control operating range in 2 dB steps
Bass tilt control operating range in 2 dB steps
The 'CAL' position is with all tone controls set to 'off' and the
input sensitivity control to maximum (fully clockwise)
International enquiries:
Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland
Phone +358 17 83881
Fax +358 17 812 267
Email genelec@genelec.com
THD
SMPTE-IM
CCIF-IM
DIM 100
Bass
Treble
Idle
Full output
In the U.S. please contact:
In China please contact:
Genelec, Inc., 7 Tech Circle
Beijing Genelec Audio Co. Ltd.
Natick, MA 01760, U.S.A.
Jianwai SOHO, Tower 12, Room 2306
Phone +1 508 652 0900
39 East 3rd Ring Road
Fax +1 508 652 0909
Chaoyang District, Beijing 100022, China
Email genelec.usa@genelec.com
Phone +86 10 5869 7915
Fax +86 10 5869 7914
8050A
150 W (6 Ohm load)
120 W (8 Ohm load)
≤ 0.05 %
≤ 0.05 %
≤ 0.05 %
≤ 0.05 %
≥ 100 dB
≥ 100 dB
100, 120, 220 or 230 V
according to region
±10 %
10 VA
170 VA
8050A
Pin 1 gnd, pin 2 +, pin 3 -
10 kOhm balanced
Adjustable from +6 to -6 dBu
1.8 kHz
From +2 to -4 dB & MUTE
@ 15 kHz
-4 dB @ 160 Hz
From 0 to -6 dB @ 35 Hz
From 0 to -6 dB & MUTE
@ 100 Hz
www.genelec.com
In Sweden please contact:
Genelec Sverige
Box 5521, S-141 05 Huddinge
Phone +46 8 449 7070
Fax +46 8 708 7071
Email info@genelec.com

Advertisement

loading