2.1 Technical data

CPU ARM Cortex M4
Class A LoRaWAN® 1.0.2 , EU868
OTAA/ABP activation
Level range 140 ÷ 1500mm, resolution 1mm, accuracy TBD
Field of View: ±15°
Non contact level detection up to 1.5mt
Internal temperature measurement (+/- 1°C typ, +/- 2°C max).
Embedded antenna
Magnetic start-up
Time interval based or thresholds based uplink
Embedded accelerometer for tilt status
Primary battery with no harmful substances, replacement possible
Pole or surface mount
5 years life time with SF12 and max Tx power, 48 Uplinks messages per day
Transmission @ 868 MHZ, 14dBm max.
BLE 5.0 interface for configuration, data reading and FW upgrade
Remote configuration
Storage temperature -30°C ÷ +80°C
Working temperature -30°C ÷ +70°C
Dimensions: 64.5×58.5x39mm
Protection grade: IP67
Weight: 90g

2.2 Installation

To ensure correct operation and reliable and consistent level measurements, install the EGK-
LW20W00 sensor on the lid interior. Screws are provided. The device measures the distance to the
closest target on its field of view. It works with different waste materials like organic, glass, paper,
plastic, residual waste.
The measure is performed periodically according to parameter Period [min].