The device exits factory activated with NONE mode. On request devices can be shipped aleady
activated.
Note: in OTAA AppKey is write only, in reading the field will always be empty, even if set.
Time sync
Normally sensor asks for a time sync at every power on (uplink starting with 01) or once a week. If no
or wrong reply received it will retry after 1 hour.
If not handled in the right way can cause a unnecessary battery consumption (battery life < 2 years).
Please check chapter 2.1

4.2 Other settings

Network settings:
please keep "Any" settings. Change it only if Objenious network is used (default_ any).
Network type:
LoRa syncword can be setted as "private"(0x12) instead "public" (0x34), but the NS must be setted
accordingly (default: public).
Band:
select the right LoRaWAN ® band settings accodingly to country requirements.
https://www.enginko.com/support/
manual_egk-lw20w00 https://www.enginko.com/support/doku.php?id=manual_egk-lw20w00
DATA FRAME
FORMAT.
www.ime.de
Printed on 2022/07/07 14:23