1039A Data Sheet
SyStem SpeciFicAtionS
1039A
Lower cut-off frequency, -3 dB
< 29 Hz
Upper cut-off frequency, -3 dB
> 20 kHz
Free field frequency response
31 Hz - 20 kHz (±2.5 dB)
Maximum short term sine wave acoustic
output on axis in half space, averaged
from 100 Hz to 3 kHz:
@ 1 m >126 dB SPL
Maximum long term RMS acoustic
output in same conditions with
IEC-weighted noise (limited by driver
unit protection circuit)
@ 1m >120 dB SPL
Maximum peak acoustic output per pair
@ 2 m from the engineer with music
material
> 130 dB
Self generated noise level in free field
@ 2 m on axis
< 15 dBA
Harmonic distortion at 100 dB SPL
Freq:
Drivers
Bass
Mid
Treble
Weight
Speaker 115 kg (253 lb)
Amplifier 22 kg (49 lb)
Speaker dimensions
Height
(Horizontal mounting)
Width
Depth
Amplifier dimensions
Height
Width
Depth
* Note that the cable connectors require additional
100 mm (4") of space behind both the amplifier
and the speaker cabinet.
Genelec Document BBA39001a. Copyright Genelec Oy 4.2007. All data subject to change without prior notice
50...200 Hz
<1%
200...10 kHz
<0.5
2 x 385 mm (15")
1 x 130 mm (5")
1 x 25 mm (1") metal dome
820 mm (32
/
")
1
4
1050 mm (39
/
")
3
8
550 mm (21
5
/
")
8
310 mm (12
3
/
")
16
483 mm (19")
250 mm (9
/
") *
13
16
International enquiries:
Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland
Phone +358 17 83 881
Fax +358 17 812 267
Email genelec@genelec.com
AmpliFier Section
Bass amplifier output power with
an 8 Ohm load
Mid amplifier output power with
an 8 Ohm load
Treble amplifier output power with
an 8 Ohm load
Slew rate
Amplifier system distortion at
nominal output
Signal to Noise ratio,
referred to full output
Mains voltage:
Voltage operating range at
230 V setting
115 V setting
Power consumption
croSSover Section
Input connector: XLR female
Input impedance
Input level for 100 dB SPL output @ 1 m
Input level for maximum short term output
of 126 dB SPL @ 1 m
Subsonic filter below 27 Hz
Ultrasonic filter above 22 kHz
Crossover frequencies
Crossover acoustical slopes
Level control operating range
in 1 dB steps
Bass roll-off control in 2 dB steps
Bass tilt control in 2 dB steps
In the U.S. please contact
In China please contact:
Genelec, Inc., 7 Tech Circle
Beijing Genelec Audio Co. Ltd.
Natick, MA 01760
Jianwai SOHO, Tower 12, Room 2306
Phone +1 508 652 0900
39 East 3rd Ring Road
Fax +1 508 652 0909
Chaoyang District
Beijing 100022, China
Email genelec.usa@genelec.com
Phone +86 10 5869 7915, Fax +86 10 5869 7914
1039A
Short term 2 x 400 W
Short term 350 W
Short term 120 W
Long term output power is limited by driver unit
protection circuitry.
80 V/µs
THD
<0.05%
SMPTE-IM
<0.05%
CCIF-IM
<0.05%
DIM 100
<0.05%
Bass
>100 dB
Mid
>100 dB
Treble
>100 dB
100/200 or 115/230 V
207 - 244 V (-10/+6 %)
104 - 122 V (-10/+6 %)
Idle
70 W
Full output
1000 W
1039A
pin 1 gnd
pin 2 +
pin 3 -
10 kOhm balanced
variable from +6 to -6 dBu
variable from +32 to +20 dBu
18 dB/octave
12 dB/octave
Bass/Mid
400 Hz
Mid/Treble
3.2 kHz
>24 dB/octave
Bass
from 0 to -6 dB & MUTE
Mid
from 0 to -6 dB & MUTE
Treble
from 0 to -6 dB & MUTE
from 0 to -8 dB @ 29 Hz
from 0 to -8 dB @ 50 Hz
The 'CAL' position is with all tone controls set to 'off'
and input sensitivity control to maximum and
corresponds to a maximally flat free field response.
www.genelec.com
In Sweden please contact
Genelec Sverige
Ellipsvägen 10B
P.O. Box 5521, S-141 05 Huddinge
Phone +46 8 449 5220
Fax +46 8 708 7071
Email info@genelec.com

Advertisement

loading