on the left side panel
You can switch the connection on the
back panel to the left side panel as
follows:
Remove the cover on the side panel.
1.
Remove the bayonet ring from the
2.
back panel and attach it to the
opening on the side panel.
Seal the opening in the back panel
3.
with the cover.
If there is a high level of
Note:
condensation in the exhaust air duct, it
is advisable to fix a condensation
collector (standard) or a drain hole with
a diameter of approximately 3 mm to
the lowest part of the exhaust air duct.
Installation and connection
Exhaust air duct
All standard products can be used for
the exhaust air duct:
flexible pipes
galvanised metal ducts or pipes
connectors, adapters and diverters
for flat duct systems and pipe
systems
wall boxes for evaporation into the
open air or into a ventilation shaft
adapters on rectangular ducts
rectangular ducts or plastic pipes
back pressure flap
The material must be heat
Note:
resistant up to 80 °C and moisture
resistant.
Pressure losses
The type and length of the
Note:
exhaust air duct, particularly elbows or
bends with small radii, can impede the
air flow. Keep diameter reductions and
pressure losses (resistance) to a
minimum.
The following must be avoided:
long exhaust air ducts
exhaust air ducts with small
diameters
exhaust air ducts with many bends
and elbows.
en
15